IPS - ESTS – DEM - Comunicações em congressos
Permanent URI for this collection
Browse
Browsing IPS - ESTS – DEM - Comunicações em congressos by Issue Date
Now showing 1 - 10 of 54
Results Per Page
Sort Options
- Numerical model of propeller vortex wakes for calculation of induced velocitiesPublication . Duarte, Rogério; Campos, J. A. C. Falcão deA numerical model for partial alignment of propeller vortex wakes with the flow is investigated. A lifting line representation of the propeller blades is used combined with the vortex lattice discretization method. The model takes into account radial contraction and axial variation of the pitch of the trailing vortices. The convergence of the iterative pitch alignment procedure and the influence of the number of vortex elements is studied in the case of an optimum moderately loaded propeller. The effects of axial variation of pitch and contraction are investigated for the same optimum circulation distribution case. The model is applied to the vortex wake of propeller DTRC 4119 and results are compared with experimental data.
- Energy rehabilitation studies of a large group of historical buildings: a case studyPublication . Teixeira, A. Rego; Duarte, Rogério; Brotas, L.; Almeida, P.; Brandão, M. A.In this paper, energy rehabilitation studies of a large group of historical buildings are assessed. A general methodology and some particular constraints are discussed. For a case study including 65 buildings in one of Lisbon’s historical centres, the methodology used, the proposed energy-efficient measures and the results in terms of heating energy savings and summer thermal convert are presented and discussed.
- Avaliação energética de um sistema híbrido radiante-convectivo a dois-tubos, ventiloconvectores e paredes radiantesPublication . Roriz, L.; Duarte, Rogério; Gamboa, M.A comparação dos sistemas radiantes com os sistemas convectivos tradicionais pode ser efectuada através da análise comparativa dos efeitos resultantes da elevação da temperatura radiante média e 1 K com os efeitos resultantes da elevação da temperatura do ar interior de 1 K. No presente artigo, introduz-se um sistema híbrido radiante-convectivo baseado no sistema a dois-tubos, ventiloconvectores e paredes radiantes para um edifício de escritórios. Com base no programa de simulação DOE2, obtém-se a poupança energética anual devida à alteração da temperatura do ar no interior da sala de 1 K nas estações de aquecimento e arrefecimento e apresentam-se resultados que demonstram que o consumo energético para a alteração de 1 K da temperatura radiante média é inferior a esta poupança energética. Discutem-se questões técnicas e relativas ao investimento necessário para implementar o sistema híbrido radiante-convectivo. Os resultados permitem concluir o interesse deste sistema híbrido radiante-convectivo.
- Glazing-related problems due to high temperatures in double skin façadesPublication . Duarte, Rogério; Leandro, S. Oliveira; Teixeira, A. Rego; Bigode, C.The thermal behaviour of a double skin façade building is modelled using the DOE-2 building energy simulation program. Maximum temperatures of glazed components of the double skin façade are determined to assess the occurrence of glazing-related problems, such as reduced thermal and aesthetic performance, increased maintenance costs and even injury hazards. The importance of detailed thermal modelling of double skin façades and of its glazed componentes is concluded.
- Monitoring of a Double Skin Façade Building: Methodology and Office Thermal and Energy PerformancePublication . Marques da Silva, F.; Duarte, Rogério; Cardoso e Cunha, L.This paper concerns to the post-occupancy monitoring of a building sited in Lisbon with transparent double-skin façades. This is the first of an enlarged monitoring program covering other buildings and weather conditions, aiming to clarify under which climate and performing conditions this architectural solution is acceptable. Within this campaign an enlarged set of parameters was measured from external conditions to energy consumption and indoor comfort. The present paper describes the building, presents the monitoring methodology and analyses the thermal and energy performance of a specific office space.
- Energy Benchmarking of Double-Skin Façade BuildingsPublication . Duarte, Rogério; Matos, M. deThis paper describes ongoing energy benchmarking studies of double-skin façade buildings. Benchmarking methodology is discussed. Some preliminary results are presented.
- A comparison between energy performance of one DSF buildings studied sample and office buildings benchmarks in EuropePublication . Matos, M. de; Duarte, RogérioThis paper describes ongoing energy benchmarks studies of double-skin façade buildings. A comparison between energy performance of these actual buildings and European office buildings benchmarks is discussed. Some preliminary results are presented.
- Climatização Geosolar em MouraPublication . Santos, Miguel; Duarte, RogérioNeste artigo faz-se a descrição de conceitos subjacentes ao sistema de climatização geosolar aplicado no novo edifício da Lógica, E.M. em Moura, incluindo-se fundamentação teórica, aspetos preditivos de funcionamento, descrição técnica, considerações quanto aos custos e sustentabilidade, e, enquadramento ao abrigo do SCE. Trata-se de um sistema de AVAC Carbono Zero, ideal para aplicação em várias latitudes, nomedamente as de Portugal Continental. Como principais conclusões deve referir-se que é possível obter uma solução deste tipo com um custo global da ordem de grandeza do de sistemas de AVAC de elevada qualidade o que significará que as poupanças dos custos com energia começam a ser sentidas desde o primeiro dia de utilização. Tornou-se ainda possível que um edifício de serviços que estaria naturalmente abrangido pelo RSECE, seja tratado ao nível do RCCTE.
- Consumo energético, conforto e qualidade do ar em salas de aula de edifícios escolares do período JCETS - MOPPublication . Duarte, Rogério; Pereira, MarcoAs infraestruturas escolares públicas existentes têm sido objeto de investimentos de renovação e melhoramento significativos num momento em que a legislação estabelece valores máximos de concentração de poluentes caracterizadores da qualidade do ar no interior dos edifícios. O cumprimento das exigências de qualidade do ar interior precipitou uma mudança de paradigma na ventilação de salas de aula em edifícios escolares, assistindo-se à adoção de sistemas mecânicos de ventilação e climatização, em contraponto com a tradicional ventilação natural. Para as equipas gestoras escolares, frequentemente desconhecedoras da importância da qualidade do ar, a ventilação mecânica constitui um sorvedouro de recursos difícil de justificar. Importa por isso estudar estratégias que permitam, por um lado garantir a qualidade do ar e o conforto nas salas de aula, mas por outro lado não imponham custos excessivos. Partindo de uma sala de aula tipo de edifícios escolares do período JCETS – MOP (Junta das Construções para o Ensino Técnico Superior – Ministério das Obras Públicas) estuda-se um sistema de ventilação mecânica que varia o caudal de ventilação em função da concentração de CO2 nas salas, comparando-se a qualidade do ar interior e o conforto com os conseguidos por ventilação natural e por ventilação mecânica com caudal constante. Compara-se ainda o custo energético dos dois sistemas de ventilação mecânica em estudo. Conclui-se que a definição da qualidade do ar no interior de edifícios assente na limitação de valores de “concentrações-hora” de poluentes (em lugar da atual e mais restritiva limitação da concentração) permitiria a salas de aula ventiladas naturalmente cumprir a legislação.
- Limiting performance analysis of a vehicle restraint systemPublication . Moita, Paulo; Cardoso, J. B.; Valido, A. J.
