Logo do repositório
 
Publicação

Utilização de um espectrofotómetro experimental para a medição simultânea de cor e brilho em medicina dentária : estudo preliminar comparativo

dc.contributor.advisorAzul, Ana Mano
dc.contributor.advisorDelgado, António Sales
dc.contributor.advisorCaldeira, Francisco Jorge
dc.contributor.authorValente, Océane Alice El Bez
dc.date.accessioned2022-12-27T10:41:09Z
dc.date.available2022-12-27T10:41:09Z
dc.date.issued2022-11-26
dc.descriptionDissertação para obtenção do grau de Mestre no Instituto Universitário Egas Monizpt_PT
dc.description.abstractIntrodução: O sucesso estético de uma restauração está diretamente relacionado com as suas propriedades óticas e a sua avaliação, na prática clínica, é atualmente subjetiva. Objetivos: Avaliar e comparar a cor e o brilho de 2 resinas compostas diretas, com auxílio de espectrofotómetro e brilhómetro. Avaliar a eficácia do novo instrumento experimental para medições óticas.. Materiais e métodos: Foram testadas 2 resinas compostas: 3MTM FiltekTM Supreme XTE (nanoparticulada) e 3MTM Filtek Z250 (microhíbrida). Foram confecionados 12 discos de cada resina em estudo, tanto na cor A1 (n=6) como na cor A4 (n=6). Os 6 discos de cada cor foram alocados aleatoriamente em 2 subgrupos, em que em 3 discos foi realizado a fotopolimerização sobre uma matriz de Mylar, sem modificações adicionais, e nos outros 3 foi aplicado o protocolo de polimento com uma lixa de papel (320 grit SiC). No final, foi feita a avaliação da cor e do brilho de todas as amostras, com auxílio dos equipamentos padrão comerciais - SpectroShadeTM Micro e Glossmeter Micro-Gloss 60º Nº4501 – e por um novo instrumento experimental de medição biaxial da cor e brilho (SARSPEC Flex), de modo a comparar os valores obtidos. Os dados laboratoriais foram analisados com recurso ao programa SPSS 28.0, com um nível de significância 5%. Resultados: A variação da resina composta não teve impacto significativo na refletância e nos parâmetros L*, a* e b* (p>0,05). A variação da cor teve resultados significativos nos parâmetros L* e b* (p<0,01), mas não sobre a refletância (p=0,885) ou sobre o parâmetro a* (p=0,068). Os diferentes acabamentos de superfície têm apenas um impacto significativo sobre a refletância (p=0,004) menos à exceção do parâmetro a* (p=0,897). Por último, o aparelho SARSPEC Flex inovador, em comparação com os aparelhos comerciais de medição de cor e brilho obteve diferenças significativas em todos os parâmetros analisados (p<0,001). Conclusões: O SARSPEC Flex apesar de ser um instrumento inovador, com medição biaxial da cor e do brilho, ainda é muito experimental, sendo necessário desenvolver mais estudos de forma a promover melhores resultados.pt_PT
dc.description.abstractIntroduction: The aesthetic success of a restoration is directly related to its optical properties and its evaluation, in clinical practice, is currently subjective. Objectives: Evaluate and compare the color and brightness of 2 direct composite resins, with the aid of spectrophotometer and brilhometer. Evaluate the effectiveness of the new instrument for optical measurements. Materials and Methods: Two composite resins were tested: 3MTM FiltekTM Supreme XTE (nanoparticle) and 3MTM Filtek Z250 (microhybrid). 12 discs of each resin under study were made, both in color A1 (n=6) and in color A4 (n=6). The 6 discs of each color were randomly allocated in 2 subgroups, in which in 3 discs, light curing was performed on a Mylar matrix, without additional modifications, and in the other 3 the polishing protocol was applied with a 320 grit SiC paper. In the end, the color and brightness of all samples were evaluated, with the aid of standard commercial equipment - SpectroShadeTM Micro and Glossmeter Micro-Gloss 60º Nº4501 - and by a new experimental instrument for biaxial color and gloss measurement (SARSPEC Flex), to compare the values obtained. Laboratory data were analyzed using the SPSS 28.0 program, with a significance level of 5%. Results: The variation of the composite resin had no significant influence on reflectance and parameters L*, a* and b* (p>0.05). The color variation had significant results in the parameters L* and b* (p<0.01), but not on the reflectance (p=0.885) or on the a* parameter (p=0.068). The different surface finishes have only a significant influence on reflectance (p=0.004) minus a* parameter (p=0.897). The SARSPEC Flex compared to the commercial color and gloss measuring devices obtained significant differences in all parameters analyzed (p<0.001). Conclusion: The SARSPEC Flex, despite being an innovative instrument, with biaxial measurement of color and brightness, is still very experimental. More research is needed to foster better results.pt_PT
dc.identifier.tid203118448pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.26/42880
dc.language.isoporpt_PT
dc.subjectResinas compostaspt_PT
dc.subjectPropriedades óticaspt_PT
dc.subjectCorpt_PT
dc.subjectBrilhopt_PT
dc.titleUtilização de um espectrofotómetro experimental para a medição simultânea de cor e brilho em medicina dentária : estudo preliminar comparativopt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
Valente_Océane_Alice_El_Bez.pdf
Tamanho:
2.07 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.85 KB
Formato:
Item-specific license agreed upon to submission
Descrição: