Publication
Comparação de técnicas de termoformação de alinhadores in-office
dc.contributor.advisor | Costa, Hélder Nunes | |
dc.contributor.author | Lima, Maria Benedita Rodrigues Palma Covas | |
dc.date.accessioned | 2022-01-14T13:33:41Z | |
dc.date.available | 2022-01-14T13:33:41Z | |
dc.date.issued | 2021-12 | |
dc.description | Dissertação para obtenção do grau de Mestre no Instituto Universitário Egas Moniz | pt_PT |
dc.description.abstract | Objetivos: Testar a viabilidade de uma técnica para avaliar se existem diferenças entre os alinhadores termoformados a vácuo e os termoformados a pressão no que toca ao ajuste dos mesmos às arcadas dentárias. Materiais e métodos: Foram termoformados 5 alinhadores sobre 5 cópias de um mesmo modelo, utilizando sempre o plástico Essix ACE®. A impressão das cópias do modelo foi realizada por uma impressora 3D e as mesmas eram constituídas por resina. Dos 5 alinhadores, 3 foram termoformados a pressão (1 experimental) e os restantes 2 a vácuo. A técnica testada consistiu na colocação da resina colorida Tensol 70 na interface alinhador/modelo. Em adição, foi elaborada a testagem de mais uma técnica. Para tal, foram realizados cortes transversais através de uma máquina de corte num molar, pré-molar e incisivo com a posterior medição da largura dos mesmos através do sistema informático ImageJ. Resultados: A técnica testada para avaliar se existem diferenças no ajuste dos alinhadores não se mostrou viável. Contudo, a técnica adicional aponta para a existência de diferenças na capacidade de ajuste dos alinhadores. Uma vez que, aos cortes dos dentes pertencentes ao alinhador termoformado a pressão corresponderam sempre valores de largura mais altos comparativamente aos obtidos pelos alinhadores termoformados a vácuo. Conclusão: O recurso à resina Tensol 70 para avaliar o ajuste dos alinhadores às arcadas dentárias não é viável. No entanto, o estudo, no seu decorrer, apontou para a existência de diferenças no ajuste dos alinhadores quando comparadas as duas técnicas de termoformação. | pt_PT |
dc.description.abstract | Objective: Test the viability of the technique to assess whether there are differences between vacuum thermoformed and pressure thermoformed aligners in terms of their adjustment to the dental arches. Materials and Method: 5 aligners were thermoformed over 5 copies of the same model, always using Essix ACE® plastic. The model copies were printed using a 3D printer and they were made of resin. Of the 5 aligners, 3 of them were thermoformed under pressure (1 experimental) and the remaining 2 under vacuum. The tested technique consisted of placing colored resin Tensol 70 at the aligner/model interface. In addition, the testing of one more technique was elaborated. To this end, cross sections were performed using a machine to cut a molar, premolar and incisor with subsequent measurement of their width using the ImageJ software. Results: The technique tested to assess whether there are differences in the adjustment of aligners was not viable. However, the additional technique points to the existence of differences in the adjustability of the aligners. Since, the cuts of teeth belonging to the pressure thermoformed aligners always corresponded to higher width values compared to those obtained by the vacuum thermoformed aligners. Conclusion: The use of Tensol 70 resin to assess the adjustment of aligners to the dental arches is not feasible. However, the study, during its course, pointed to the existence of differences in the adjustment of the aligners when comparing the two thermoforming techniques. | pt_PT |
dc.identifier.tid | 202839249 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.26/38872 | |
dc.language.iso | por | pt_PT |
dc.subject | Clear Aligners® | pt_PT |
dc.subject | Alinhadores invisíveis | pt_PT |
dc.subject | Invisalign® | pt_PT |
dc.subject | Avaliação da cor | pt_PT |
dc.title | Comparação de técnicas de termoformação de alinhadores in-office | pt_PT |
dc.type | master thesis | |
dspace.entity.type | Publication | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | masterThesis | pt_PT |
thesis.degree.name | Mestrado Integrado em Medicina Dentária | pt_PT |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Lima_Maria_Benedita_Rodrigues_Palma_Covas.pdf
- Size:
- 2.34 MB
- Format:
- Adobe Portable Document Format