Browsing by Author "Graveto, João"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- Modelo conceptual versus “modelo oculto” para a (na) prática da enfermagemPublication . Silva, Margarida Alexandra; Graveto, João
- Nursing Students' Perceptions of a Novel Education Approach to Prevention and Control of Healthcare-Associated Infections: Insights from PrevInf Pilot StudyPublication . Santos-Costa, Paulo; Paiva-Santos, Filipe; Graveto, João; PrevInf GroupHealthcare-associated infections (HAIs) pose a significant global threat, particularly in developing regions such as Southeast Asia. International bodies emphasize the role of formal undergraduate training in the prevention and control of HAIs. To address this, we aimed to explore the perceptions of Southeast Asian nursing students regarding a novel educational approach developed by a European–Southeast Asian project consortium. Methods: A pilot study was conducted in four nursing higher education institutions from Cambodia and Vietnam. First, local nursing educators conducted a 2 h classroom-based training session. Then, students were invited to participate for the first time in one of twelve evidence-based simulation scenarios developed by the research team, covering a range of nursing care situations related to the prevention and control of HAIs. After attending both components, students were asked to complete a paper-based questionnaire and rate their agreement with a set of statements on the appropriateness and meaningfulness of both components. Results: A total of 430 nursing students enrolled in the pilot study; 77.4% were female, with an average age of 19.8 years. The PrevInf educational intervention received positive feedback from participating students across settings, with strong agreement on the importance of proactiveness in competency development (M = 5.9, SD = 1.4). Notable differences between Cambodian and Vietnamese students were observed in terms of their receptiveness to the pre-selected teaching materials (p = 0.001) and strategies (p = 0.01) used by the nursing educators during their experience with the simulation scenarios. Conclusions: The PrevInf educational intervention shows promise in engaging Southeast Asian nursing students and fostering a deeper understanding of the prevention and control of HAIs. Further studies are warranted to refine the learning content and standardize the pedagogical strategies used by nursing educators across settings. This study was not registered.
- Short peripheral venous catheters contamination and the dangers of bloodstream infection in Portugal: an analytic studyPublication . Osório, Nádia; Oliveira, Vânia; Costa, Maria Inês; Santos-Costa, Paulo; Serambeque, Beatriz; Gama, Fernando; Adriano, David; Graveto, João; Parreira, Pedro; Salgueiro-Oliveira, AnabelaPeripheral venous catheters (PVCs) are the most used vascular access devices in the world. However, failure rates remain considerably high, with complications such as PVC-related infections posing significant threats to patients’ well-being. In Portugal, studies evaluating the contamination of these vascular medical devices and characterizing the associated microorganisms are scarce and lack insight into potential virulence factors. To address this gap, we analyzed 110 PVC tips collected in a large tertiary hospital in Portugal. Experiments followed Maki et al.’s semi-quantitative method for microbiological diagnosis. Staphylococcus spp. were subsequently studied for the antimicrobial susceptibility profile by disc diffusion method and based on the cefoxitin phenotype, were further classified into strains resistant to methicillin. Screening for the mecA gene was also done by a polymerase chain reaction and minimum inhibitory concentration (MIC)-vancomycin as determined by E-test, proteolytic and hemolytic activity on skimmed milk 1% plate and blood agar, respectively. The biofilm formation was evaluated on microplate reading through iodonitrotetrazolium chloride 95% (INT). Overall, 30% of PVCs were contaminated, and the most prevalent genus was Staphylococcus spp., 48.8%. This genus presented resistance to penicillin (91%), erythromycin (82%), ciprofloxacin (64%), and cefoxitin (59%). Thus, 59% of strains were considered resistant to methicillin; however, we detected the mecA gene in 82% of the isolates tested. Regarding the virulence factors, 36.4% presented α-hemolysis and 22.7% β-hemolysis, 63.6% presented a positive result for the production of proteases, and 63.6% presented a biofilm formation capacity. Nearly 36.4% were simultaneously resistant to methicillin and showed expression of proteases and/or hemolysins, biofilm formation, and the MIC to vancomycin were greater than 2 µg/mL. Conclusion: PVCs were mainly contaminated with Staphylococcus spp., with high pathogenicity and resistance to antibiotics. The production of virulence factors strengthens the attachment and the permanence to the catheter’s lumen. Quality improvement initiatives are needed to mitigate such results and enhance the quality and safety of the care provided in this field.