Publication
Restaurações provisórias em CAD/CAM sobre dente : estética e cor
| dc.contributor.advisor | Martins, Francisco | |
| dc.contributor.author | Mata, Ricardo Jorge da Conceição | |
| dc.date.accessioned | 2024-12-16T15:39:36Z | |
| dc.date.embargo | 2027-11-23 | |
| dc.date.issued | 2024-11-23 | |
| dc.description | Dissertação para obtenção do grau de Mestre no Instituto Universitário Egas Moniz | pt_PT |
| dc.description.abstract | Objetivo: Avaliar in vitro as alterações de cor em restaurações provisórias feitas com dois materiais CAD/CAM de diferentes espessuras aplicados sobre dentes bovinos. Materiais e Métodos: Foram utilizados dois tipos de materiais restauradores provisórios CAD/CAM: VITA CAD-Temp® A2 e Telio® CAD A2. Foram preparados dois grupos de 40 amostras cada, um para cada material. As amostras foram divididas em subgrupos de quatro espessuras diferentes: 0,5mm, 0,8mm, 1mm e 2mm. Assim, cada subgrupo continha 10 amostras. Todos os corpos de prova foram fresados e polidos com lixas de carbeto de silício de grão 500, 1000 e 1500 para garantir uma superfície uniforme. Após o preparo, as amostras foram emparelhadas com um dente bovino, e a cor foi analisada antes e após o emparelhamento utilizando um espectrofotómetro VITA Easyshade® V. A análise estatística foi realizada por meio de ANOVA de dois fatores e comparações múltiplas com o método de Bonferroni (nível de significância de 95%). Resultados: A análise da variação de cor (ΔEab) demonstrou que o material VITA CAD-Temp® A2 apresentou uma variação de cor mais estável em todas as espessuras comparativamente ao Telio® CAD A2. Para o VITA CAD-Temp® A2, as espessuras de 0,5mm, 0,8mm e 1mm mostraram valores de ΔEab semelhantes, com um aumento na espessura de 2mm resultando numa maior alteração de cor. No Telio® CAD A2, as espessuras menores (0,5mm e 0,8mm) apresentaram maior variação de cor, enquanto a espessura de 1mm mostrou a menor variação. O aumento da espessura mostrou-se eficaz na redução da variação de cor para ambos os materiais. Conclusões: O material VITA CAD-Temp® A2 demonstrou maior estabilidade de cor comparado ao Telio® CAD A2, principalmente nas espessuras menores. Em ambos os materiais, a espessura maior proporcionou uma coloração mais estável e uniforme. | pt_PT |
| dc.description.abstract | Objective: To evaluate in vitro the colour changes in provisional restorations made with two CAD/CAM materials of different thicknesses applied to bovine teeth. Materials and Methods: Two types of CAD/CAM provisional restorative materials were used: VITA CAD-Temp® A2 and Telio® CAD A2. Two groups of 40 samples each were prepared, one for each material. The samples were divided into subgroups with four different thicknesses: 0,5mm, 0,8mm, 1mm, and 2mm. Each subgroup contained 10 samples. All specimens were milled and polished with silicon carbide (SiC) abrasive papers with grits of 500, 1000, and 1500 to ensure a uniform surface. After preparation, the samples were paired with a bovine tooth, and colour measurements were taken before and after pairing using a VITA Easyshade® V spectrophotometer. Statistical analysis was performed using a two-factor ANOVA and multiple comparisons with the Bonferroni method (95% significance level). Results: The analysis of colour variation (ΔEab) showed that the VITA CAD-Temp® A2 material presented more stable colour variation at all thicknesses compared to Telio® CAD A2. For VITA CAD-Temp® A2, thicknesses of 0,5mm, 0,8mm, and 1mm showed similar ΔEab values, with an increase in thickness to 2mm resulting in greater colour change. For Telio® CAD A2, the thinner samples (0,5mm and 0,8mm) exhibited greater colour variation, while the 1mm thickness showed the least variation. Increasing the thickness proved effective in reducing colour variation for both materials. Conclusions: The VITA CAD-Temp® A2 material demonstrated greater colour stability compared to Telio® CAD A2, particularly at smaller thicknesses. In both materials, a greater thickness provided more stable and uniform coloration. | pt_PT |
| dc.identifier.tid | 203745191 | pt_PT |
| dc.identifier.uri | http://hdl.handle.net/10400.26/53171 | |
| dc.language.iso | por | pt_PT |
| dc.subject | CAD/CAM | pt_PT |
| dc.subject | Restaurações provisórias | pt_PT |
| dc.subject | Alterações de cor | pt_PT |
| dc.subject | Dente | pt_PT |
| dc.title | Restaurações provisórias em CAD/CAM sobre dente : estética e cor | pt_PT |
| dc.type | master thesis | |
| dspace.entity.type | Publication | |
| rcaap.rights | embargoedAccess | pt_PT |
| rcaap.type | masterThesis | pt_PT |
| thesis.degree.name | Mestrado Integrado em Medicina Dentária | pt_PT |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Mata_Ricardo_Jorge_da_Conceição.pdf
- Size:
- 834.61 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.85 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
