Repository logo
 
Publication

Avaliação dos valores de exposição de dose no acidente vascular cerebral

datacite.subject.fosCiências Médicaspt_PT
dc.contributor.advisorRodrigues dos Santos, Joana Margarida
dc.contributor.advisorAlves Ventura de Oliveira Veiga, Ricardo Jorge
dc.contributor.authorda Silva Carvalho, Ana Filipa
dc.date.accessioned2025-01-21T16:04:04Z
dc.date.available2025-01-21T16:04:04Z
dc.date.issued2024-12-19
dc.date.submitted2024-11-06
dc.description.abstractIntrodução: Sendo as doenças cerebrovasculares uma das principais causas de morte prematura e de incapacidade na Europa, com mais de 12,2 milhões de Acidentes Vasculares Cerebrais (AVC) registados anualmente, prevê-se que uma em cada quatro pessoas com mais de 25 anos sofrerá um AVC ao longo da vida. Assim, a via verde AVC melhora a eficiência do diagnóstico e tratamento, envolvendo o uso de radiação ionizante desde o diagnóstico até o tratamento. Objetivo: Estabelecer Níveis de Referência de Diagnóstico (NRD) locais nas modalidades que utilizam radiação ionizante, incluindo radiografia, tomografia computorizada (TC) e fluoroscopia e avaliar a dose efetiva em AVC isquémico e hemorrágico desde o diagnóstico até à alta clínica. Métodos: Foi realizado um estudo retrospetivo com dados de exames de doentes com diagnóstico de AVC na Unidade Local de Saúde (ULS) de Coimbra, recolhidos ao longo de um ano (2022). Foram analisados o número de exames, os parâmetros de exposição e os descritores de dose como Kerma Area Product (KAP - Gy.cm2), AirKerma (k) tempo de fluoroscopia (minutos), número de imagens, Dose-Length Product (DLP) e Computed Tomography Dose Index volume (CTDIvol). Os NRD foram arredondados a partir do terceiro quartil. Foram também analisados os valores das escalas Alberta Stroke Programme Early CT Score (ASPECTS), Oxfordshire Community Stroke Project (OSCSP) e Thrombolysis in Cerebral Infarction (TICI). Resultados: Foram estabelecidos NRD locais para AVC isquémico e hemorrágico. Para AVC isquémico, os valores foram: radiografia torácica com KAP de 363 mGy.cm²; TC diagnóstico com DLP de 1887 mGy.cm e CTDIvol de 34 mGy; TC de controlo com DLP de 1119 mGy.cm e CTDIvol de 69 mGy; e fluoroscopia com KAP de 231 Gy.cm² e AirKerma de 1616 mGy. Resultando numa dose efetiva total de 28 mSv para AVC isquémico. Para AVC hemorrágico, a TC diagnóstico apresentou DLP de 1180 mGy.cm e CTDIvol de 68 mGy, enquanto a TC de controlo deteve um valor de DLP de 1156 mGy.cm e CTDIvol de 69 mGy, com uma dose efetiva de 5 mSv.Conclusão: Determinaram-se os valores de NRD Locais e a respetiva dose efetiva para o AVC isquémico e hemorrágico. Os valores obtidos foram na generalidade superiores às recomendações internacionais. A implementação destes NRD pretende melhorar a prática clínica, promovendo a segurança do doente e a comunicação informada sobre os riscos da radiação ionizante.pt_PT
dc.description.abstractIntroduction: Cerebrovascular diseases are among the leading causes of premature death and disability in Europe, with over 12,2 million strokes recorded annually. It is estimated that one in four people over 25 will experience a stroke in their lifetime. The stroke pathway improves the efficiency of diagnosis and treatment, involving the use of ionizing radiation from diagnosis to treatment. Objective: To establish local DRLs and evaluate the effective dose for ischemic and hemorrhagic stroke during hospitalization, across modalities using ionizing radiation, including radiography, computed tomography (CT), and fluoroscopy. Methods: A retrospective study was conducted with data collected over one year (2022) in patients diagnosed with ischemic and hemorrhagic stroke in the Local Health Unit of Coimbra. The number of exams, exposure parameters and dose descriptors such as Kerma Area Product (KAP), AirKerma (k), fluoroscopy time, number of images, Dose Length Product (DLP), and Computed Tomography Dose Index volume (CTDIvol) were analyzed. DRLs were rounded from the third quartile, and values from the Alberta Stroke Programme Early CT Score (ASPECTS), Oxfordshire Community Stroke Project (OSCSP), and Thrombolysis in Cerebral Infarction (TICI) scales were also assessed. Results: Local DRLs were established for ischemic and hemorrhagic stroke. For ischemic stroke, the values were: chest X-ray with KAP of 363 mGy·cm²; diagnostic CT with DLP of 1887 mGy.cm and CTDIvol of 34 mGy; control CT with DLP of 1119 mGy.cm and CTDIvol of 69 mGy; and fluoroscopy with KAP of 231 Gy.cm² and AirKerma of 1616 mGy. The number of images was 349 and the fluoroscopy time was 18 minutes, resulting in a total effective dose of 28 mSv. For hemorrhagic stroke, diagnostic CT showed DLP of 1180 mGy.cm and CTDIvol of 68 mGy, while control CT had DLP of 1156 mGy.cm and CTDIvol of 69 mGy, with an effective dose of 5 mSv. Conclusion: Local DRL values and the respective effective dose for ischemic and hemorrhagic stroke were determined. The values obtained were generally higher than international recommendations. The implementation of these DRLs aims to improve clinical practice, promoting patient safety and informed communication about the risks of ionizing radiation.pt_PT
dc.identifier.tid203825217
dc.identifier.urihttp://hdl.handle.net/10400.26/53943
dc.language.isoporpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/pt_PT
dc.subjectNível de referência de diagnósticopt_PT
dc.subjectProteção radiológicapt_PT
dc.subjectAcidente vascular cerebralpt_PT
dc.subjectTomografia computorizadapt_PT
dc.subjectAngiografiapt_PT
dc.subjectDiagnostic reference levelspt_PT
dc.subjectRadiation protectionpt_PT
dc.subjectStrokept_PT
dc.subjectComputed tomographypt_PT
dc.subjectAngiographypt_PT
dc.titleAvaliação dos valores de exposição de dose no acidente vascular cerebralpt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado em Imagem Médica e Radioterapiapt_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
5 - Trabalho submetido a 06-11-2024 19h15-Ana Filipa Carvalho.pdf
Size:
2.89 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: