Repository logo
 
Publication

O recurso ao sistema T-Scan na avaliação do impacto das cargas oclusais em reabilitações implanto-suportadas

dc.contributor.advisorFélix, Sérgio Antunes
dc.contributor.advisorMartins, Leonardo
dc.contributor.authorLenel, Gaétan Frédéric Marie
dc.date.accessioned2019-10-03T08:41:14Z
dc.date.available2019-10-03T08:41:14Z
dc.date.issued2019-07
dc.descriptionDissertação para obtenção do grau de Mestre no Instituto Universitário Egas Monizpt_PT
dc.description.abstractA natureza deletéria das sobrecargas oclusais em reabilitação oral já é conhecida de há muitos anos. A anquilose funcional do implante e a perda de propriocepção contribuem para que a sobrecarga oclusal seja um factor de risco importante em reabilitações implanto-suportadas. No entanto, a evolução dos protocolos e os estudos mostrando a viabilidade da colocação de implante com carga imediata traduzem as imprecisões sobre o conhecimento do impacto das cargas oclusais em reabilitações implanto-suportadas. O sistema T-Scan, cuja primeira versão foi produzida em 1987 e aperfeiçoada até sua versão Novus comercializada em 2015, permitiria, segundo a literatura, caracterizar com mais precisão as cargas oclusais em questão. Assim, esta revisão tem como objetivo responder às seguintes problemáticas: O recurso ao sistema TScan é clinicamente recomendado como uma ferramenta diagnóstica da sobrecarga oclusal em reabilitações implanto-suportadas, ao invés de ferramentas convencionais, como o papel químico? E finalmente, qual é o impacto real das cargas oclusais na saúde do implante? A síntese dos resultados dos estudos publicados desde 2010 nas bases de dados científicas reconhecidas permite chegar às seguintes conclusões: Se por um lado o nível de evidência científica relativa à recomendação do uso clínico do sistema T-Scan precisa ser fortalecido cientificamente, a sua superioridade em termos de capacidade de reprodutibilidade, objetividade e precisão em relação às técnicas convencionais parecem ser suficientes para a aprovação da sua aplicação clínica. Além disso, embora as complicações mecânicas observadas ao longo prazo em reabilitações implanto-suportadas estejam efetivamente associadas ao fenómeno de sobrecargas oclusais, a literatura atual não permite concluir que exista uma associação significativa entre a presença de sobrecargas oclusais e o surgimento de complicações biológicas ao nível das reabilitações implanto-suportadas.pt_PT
dc.description.abstractFor several years the deleterious nature of occlusal overloads in oral rehabilitation is known. Functional ankylosis of the implant and loss of proprioception make occlusal overload a major risk factor in implant-supported rehabilitations. However, the evolution of protocols and studies showing the viability of immediate loading implants now reflect inaccuracies concerning the knowledge of the impact of occlusal loads in implantsupported rehabilitations. The T-Scan system, the first version of which was designed in 1987 and perfected until its Novus version produced in 2015, would allow, according to the literature, to characterize more precisely the occlusal loads in question. Thus, this revision aims to answer the following questions: Is the use of the T-Scan system clinically recommended as a diagnostic tool for occlusal overload in implant-supported rehabilitations rather than conventional tools such as articulating paper? And finally, what is the real impact of the occlusal load on the health of the implant? The synthesis of the conclusions published since 2010 in the recognized scientific databases allow us to reach the following conclusions: If the level of evidence concerning the recommendation of the clinical use of the T-Scan system needs to be strengthened scientifically, its superiority in terms of reproducibility, objectivity and accuracy compared to conventional techniques seems approved. Furthermore, although the long-term mechanical complications observed in implant-supported rehabilitations are effectively associated with the phenomenon of occlusal overload, the current literature does not allow us to conclude that there is a significant association between the presence of occlusal overloads and the appearance of biological complications around implant-supported rehabilitations.pt_PT
dc.identifier.tid202280446pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.26/29870
dc.language.isoporpt_PT
dc.subjectT-Scanpt_PT
dc.subjectSobrecarga oclusalpt_PT
dc.subjectComplicaçõespt_PT
dc.subjectReabilitações implanto-suportadaspt_PT
dc.titleO recurso ao sistema T-Scan na avaliação do impacto das cargas oclusais em reabilitações implanto-suportadaspt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Lenel_Gaétan_Frédéric_Marie.pdf
Size:
8.37 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: