This article proposes a novel methodology to determine the optimal number of pressure
sensors for the real-time monitoring of water distribution networks based on a quality hypervolume
indicator. The proposed methodology solves the optimization problem for different numbers of
pressure sensors, assesses the gain of installing each set of sensors by means of the hypervolume
indicator and determines the optimal number of sensors by the variation of the hypervolume indicator.
The methodology was applied to a real case study. Several robustness analyses were carried out. The
results demonstrate that the methodology is hardly influenced by the method parameters and that a
reasonable estimation of the optimal number of sensors can be easily achieved.
Description
Keywords
Real-time monitoring; Pressure sensors Optimization Multi-objective Hypervolume
Citation
Ferreira, B., Carriço, N., & Covas, D. (2021). Optimal Number of Pressure Sensors for Real-Time Monitoring of Distribution Networks by Using the Hypervolume Indicator. Water, 13, 2235.