Repository logo
 
Publication

A Comparison Among Three Multiplex Y-STR Profiling Kits for Sexual Assault Cases

dc.contributor.authorFerreira-Silva, Benedita
dc.contributor.authorFonseca-Cardoso, Margarida
dc.contributor.authorPorto, Maria João
dc.contributor.authorMagalhães, Teresa
dc.contributor.authorCainé, Laura
dc.date.accessioned2023-02-16T15:22:06Z
dc.date.available2023-02-16T15:22:06Z
dc.date.issued2018
dc.description.abstractBiological evidence of sexual assault is one of the most difficult sample types to analyze in forensic laboratories. Y-STR markers are thus a valuable tool for analyzing these samples. The aim of this project was to compare three Y-STR commercial kits by analyzing their amplification performance on casework samples. Overall, 247 trace samples were analyzed with a Yfiler® Plus PCR Amplification Kit (Applied Biosystems), PowerPlex® Y23 (Promega® ) System and AmpFLSTR® Yfiler™ PCR Amplification Kit (Applied Biosystems). Comparing the amplification performance of the three kits, the first two were significantly more sensitive than the latter (p < 0.001). For samples, with a male DNA quantity less than 0.5 ng, the PowerPlex Y23® kit was the most sensitive and best performing kit, followed by the Yfiler® Plus kit (p = 0.009). In conclusion, the Yfiler® Plus and PowerPlex Y-23® kits are viable alternatives to older kits for samples with low amounts of male DNA.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationFerreira-Silva, B., Fonseca-Cardoso, M., Porto, M. J., Magalhães, T., & Cainé, L. (2018). A Comparison Among Three Multiplex Y-STR Profiling Kits for Sexual Assault Cases. Journal of forensic sciences, 63(6), 1836–1840.pt_PT
dc.identifier.doi10.1111/1556-4029.13757pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.26/43880
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherWileypt_PT
dc.relation.publisherversionhttps://onlinelibrary.wiley.com/doi/10.1111/1556-4029.13757pt_PT
dc.subjectDNA typingpt_PT
dc.subjectForensic geneticspt_PT
dc.subjectSexual assaultpt_PT
dc.titleA Comparison Among Three Multiplex Y-STR Profiling Kits for Sexual Assault Casespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage1840pt_PT
oaire.citation.startPage1836pt_PT
oaire.citation.titleJournal of Forensic Sciencespt_PT
oaire.citation.volume63 (6)pt_PT
person.familyNameCainé
person.givenNameLaura
person.identifierAAR-9087-2020
person.identifier.ciencia-id021A-33DD-869D
person.identifier.orcid0000-0002-6542-4256
person.identifier.scopus-author-id2311978
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication1a1e1ffc-1439-48f2-a4c3-359c66db3ad1
relation.isAuthorOfPublication.latestForDiscovery1a1e1ffc-1439-48f2-a4c3-359c66db3ad1

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2018_JFS_Ferreira-Silva.pdf
Size:
101.42 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: