Repository logo
 
Publication

Progressão do desgaste dentário em esmalte e resina composta : estudo in vitro

dc.contributor.advisorVieira, Ana Maria
dc.contributor.authorLima, Luísa Andrade Palmeira
dc.date.accessioned2023-01-06T16:07:38Z
dc.date.available2023-01-06T16:07:38Z
dc.date.issued2022-12-10
dc.descriptionDissertação para obtenção do grau de Mestre no Instituto Universitário Egas Monizpt_PT
dc.description.abstractObjetivos: Este estudo teve como objetivo avaliar e comparar a progressão do desgaste dentário em amostras de esmalte humano e resina composta, in vitro, utilizando um scanner intraoral. A capacidade deste scanner para medir a progressão do desgaste também foi testada. Materiais e Métodos: O estudo foi realizado com 12 pares de amostras (cúspide de esmalte humano (CR) - amostra plana de resina composta (R)) e 12 pares de controlo (cúspide de esmalte humano (CE) - amostra plana de esmalte humano (E)), que foram submetidos a ciclos de desgaste dentário simulando a atrição na máquina Chewing Simultor CS-4. Foram efetuados 360.000 ciclos de desgaste durante 4 dias em saliva artificial à temperatura ambiente. A superfície das amostras foi scaneada com um scanner intraoral antes do início do desgaste (t0), após 1 dia de desgaste (t1), após 2 dias (t2) e no final de 4 dias (t4). A perda de volume (%vol rel) das amostras ao longo dos ciclos de desgaste foi calculada com um software desenvolvido para o efeito, e os grupos de estudo e controlo foram comparados estatisticamente. Resultados: A média da % vol rel para cada grupo em t1, t2 e t4 foi, respetivamente, para o grupo EC 98,83 ± 0,91 / 98,50 ± 0,96 / 97,70 ± 1,29, para o grupo E 99,63 ± 0,15 / 99,31 ± 0,55 / 98,97 ± 0,65, para o grupo CR 98,38 ± 2,18 / 97,60 ± 3,49 / 96,85 ± 4,55 e para o grupo R 99,19 ± 0,60 / 99,71 ± 0,78 / 98,31 ± 0,93. Houve uma redução no volume das amostras ao longo do tempo, que foi estatisticamente significativa para todos os grupos (p<0,0005). Não foram encontradas diferenças significativas entre os grupos ao longo do tempo. Conclusões: Os dados obtidos a partir dos scanners intraorais revelaram que não houve diferenças significativas entre o desgaste do esmalte e da resina composta submetida ao processo de atrição, e que o scanner intraoral pode ser uma vantagem quando utilizado como ferramenta de avaliação e diagnóstico do desgaste dentário, uma vez que é capaz de medir a progressão do desgaste.pt_PT
dc.description.abstractAims: This study aimed to evaluate and compare the progression of dental wear in samples of human enamel and composite resin, in vitro, using an intraoral scanner. The ability of this scanner to measure the progression of wear was also tested. Materials and Methods: The study was performed with 12 pairs of samples (human enamel cusp (CR) – flat composite resin sample(R)) and 12 control pairs (human enamel cusp (EC) – human enamel flat sample (E)), which were subjected to cycles of tooth wear simulating attrition on a Chewing Simulator CS-4 machine. 360,000 wear cycles were performed over 4 days in artificial saliva at room temperature. The surface of the samples was scanned with an intraoral scanner before the start of wear (t0), after 1 day of wear (t1), after 2 days (t2) and at the end of 4 days (t4). The volume loss (%vol rel) of the samples over the wear cycles was calculated with a software developed for this purpose, and the study and control groups were statistically compared. Results: The average %vol rel for each group at t1, t2 and t4 was, respectively, for group EC 98.83 ± 0.91 / 98.50 ± 0.96 / 97.70 ± 1.29, for group E 99.63 ± 0.15 / 99.31 ± 0.55 / 98.97 ± 0.65, for group CR 98.38 ± 2.18 / 97 .60 ± 3.49 / 96.85 ± 4.55 and for group R 99.19 ± 0.60 / 99.71 ± 0.78 / 98.31 ± 0.93. There was a reduction in the volume of the samples over time, which was statistically significant for all groups (p<0.0005). No significant differences were found between the groups in each time point. Conclusions: The data obtained from the intraoral scanners revealed that there were no significant differences between the wear of enamel and composite resin submitted to the attrition process, and that the intraoral scanner can be an asset when used as an assessment and diagnosis tool of dental erosion, as it can measure the progression of wear.pt_PT
dc.identifier.tid203131193pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.26/43026
dc.language.isoporpt_PT
dc.subjectDesgaste dentáriopt_PT
dc.subjectAtrição dentáriapt_PT
dc.subjectScanner intraoralpt_PT
dc.subjectChewing simulatorpt_PT
dc.titleProgressão do desgaste dentário em esmalte e resina composta : estudo in vitropt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsrestrictedAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado Integrado em Medicina Dentáriapt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Lima_Luísa_Andrade_Palmeira.pdf
Size:
3.5 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: