dc.description.abstract | Objetivo: Investigar as metodologias para detetar padrões de crises epiléticas, utilizando registos simultâneos de EEG de escalpe (scEEG) e stereo-EEG (SEEG). Ao aplicar estas técnicas avançadas de eletroencefalografia, visamos abordar desafios na gestão da epilepsia farmacorresistente e, em última análise, melhorar a qualidade de vida dos indivíduos afetados. Métodos: O protocolo do estudo foi registado no PROSPERO e seguiu as diretrizes PRISMA. Realizámos uma pesquisa abrangente nas bases de dados Scopus, PubMed e Web of Science, com foco em estudos em português ou inglês que envolvessem pacientes com epilepsia farmacorresistente que tenham realizado, simultaneamente, scEEG e SEEG. Foram excluídos estudos sem dados, revisões sistemáticas, resumos de conferências, relatos de caso(s) clínico(s) e todos os que apresentassem apenas scEEG e eletrocorticografia em simultâneo. A revisão avaliou sistematicamente os padrões de crises detetados em registos simultâneos de scEEG e SEEG. Resultados: A pesquisa identificou inicialmente 9.750 estudos, dos quais dezasseis foram considerados potencialmente elegíveis, após a triagem, sendo selecionados para revisão do texto integral. Destes dezasseis, oito estudos cumpriram os critérios de inclusão e foram incluídos na revisão: todos observacionais retrospetivos, metade deles realizados nos Estados Unidos da América e metade na Europa. Estes estudos analisaram 250 pacientes, destacando vários aspetos dos registos simultâneos de scEEG e SEEG, incluindo padrões de crises e latência entre métodos de deteção. Conclusões: Esta revisão destaca o potencial da combinação de scEEG e SEEG para melhorar a análise dos padrões de crise epilética na epilepsia farmacorresistente. A utilização simultânea de ambas as modalidades fornece informações complementares sobre o início e a propagação das crises, melhorando a localização das zonas epileptogénicas. O SEEG é eficaz na deteção de padrões ictais em zonas profundas do cérebro, enquanto o scEEG fornece dados corticais amplos que orientam a implantação do SEEG. Apesar destes benefícios, o número limitado de estudos e as inconsistências metodológicas representam desafios. Futuras investigações devem padronizar métodos, aumentar o tamanho das amostras e integrar outras técnicas de corregisto para melhorar a precisão do diagnóstico e o planeamento cirúrgico. | pt_PT |
dc.description.abstract | Purpose: To investigate methodologies for detecting seizure patterns using simultaneous scalp EEG (scEEG) and stereo-EEG (SEEG) recordings. By leveraging these advanced electroencephalographic techniques, we aim to address challenges in drug-resistant epilepsy management and ultimately improve the quality of life for affected individuals. Methods: The study protocol was registered in PROSPERO and adhered to PRISMA guidelines. We conducted a comprehensive search across Scopus, PubMed, and Web of Science, focusing on studies in Portuguese or English, involving patients with drug-resistant epilepsy who underwent simultaneous scEEG and SEEG. Studies without data, systematic reviews, conference abstracts, case reports, and those featuring only scEEG and electrocorticography were excluded. The review systematically assessed seizure patterns detected in simultaneous scEEG and SEEG recordings. Results: The search initially identified 9,750 studies, of which sixteen were potentially eligible after screening and were selected for full-text review. Of these sixteen, eight studies met the inclusion criteria and were included in the review, all retrospective observational, with half conducted in the US and half in Europe. These studies analysed 250 patients, focusing on several aspects of simultaneous scEEG and SEEG recordings, including seizure patterns and latency between detection methods. Conclusions: This review highlights the potential of combining scEEG and SEEG to enhance seizure pattern analysis in drug-resistant epilepsy. The simultaneous use of both modalities offers complementary insights into seizure onset and propagation, improving the localization of epileptogenic zones. SEEG is effective in detecting deep brain patterns, while scEEG provides broad cortical data that guides SEEG placement. Despite these benefits, the limited number of studies and methodological inconsistencies pose challenges. Future research should standardize methods, increase sample sizes, and integrate other co-registration techniques to further improve diagnostic accuracy and surgical planning. | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.26/54315 | |
dc.language.iso | por | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | pt_PT |
dc.subject | Eletroencefalograma | pt_PT |
dc.subject | Stereo-EEG | pt_PT |
dc.subject | EEG de escalpe | pt_PT |
dc.subject | Descargas epiléticas | pt_PT |
dc.subject | Electroencephalogram | pt_PT |
dc.subject | Stereo-EEG | pt_PT |
dc.subject | Scalp-EEG | pt_PT |
dc.subject | Epileptic discharges | pt_PT |
dc.title | Detecting seizure patterns: a systematic review of simultaneous scalp and stereo- electroencephalogram (EEG) | pt_PT |
dc.type | master thesis | |
dspace.entity.type | Publication | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | masterThesis | pt_PT |
thesis.degree.name | Mestrado em Fisiologia Clínica | pt_PT |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 5 - Trabalho submetido a 03-10-2024 16h36 - Cristiana Sofia Antunes dos Santos.pdf
- Size:
- 548.36 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.85 KB
- Format:
- Item-specific license agreed upon to submission
- Description: