Publication
Resistência adesiva à dentina por microtração de um sistema adesivo self-etch de baixo custo
| dc.contributor.advisor | Fernandes, Inês Caldeira | |
| dc.contributor.advisor | Costa, Joana Vieira Almeida e | |
| dc.contributor.advisor | Azul, Ana Mano | |
| dc.contributor.author | Sequeval, Valentin Guy | |
| dc.date.accessioned | 2025-11-21T15:48:27Z | |
| dc.date.available | 2025-11-21T15:48:27Z | |
| dc.date.issued | 2025-10-25 | |
| dc.description | Dissertação para obtenção do grau de Mestre no Instituto Universitário Egas Moniz | |
| dc.description.abstract | Objetivos: Avaliar in vitro a resistência adesiva à dentina por microtração de um sistema adesivo self-etch de baixo custo (OliEtch Bond, Olident, Podleze, Polónia), em comparação com um sistema adesivo universal já estabelecido. Materiais e métodos: 20 molares humanos extraídos há menos de seis meses, após limpeza e desinfecção, foram seccionados para exposição da dentina, sendo posteriormente simulada a smear-layer. Os dentes foram distribuídos aleatoriamente em dois grupos experimentais (n = 10), de acordo com o sistema adesivo utilizado: grupo controlo SBU (Scotchbond™ Universal Plus - 3M ESPE) e grupo experimental OEB (OliEtch Bond - Olident) aplicados de acordo com as instruções do fabricante. Em seguida foram colocados incrementos de 2 mm de resina composta até atingir 6 mm de altura, sendo estes fotopolimerizados de acordo com as instruções do fabricante. Os dentes foram armazenados em saliva artificial a 37 ºC durante 24 h e, em seguida, seccionados para obtenção de palitos 1 ± 0,4 mm². Estes foram submetidos a testes de microtração numa máquina de testes universal (1 kN; 0,5 mm/min). O valor médio por dente foi considerado como unidade experimental. Os dados foram analisados no programa SPSS através de uma análise estatística descritiva e inferencial com teste t de Student (α = 0,05). As falhas foram classificadas como adesivas, coesivas ou mistas por análise microscópica e a interface adesiva foi observada com o microscópio eletrónico de varrimento. Resultados: Não se observaram diferenças estatisticamente significativas na resistência adesiva à dentina por microtração entre os dois adesivos universais (t-teste; p > 0,05). A falha adesiva foi a mais prevalente em ambos os grupos e a microscopia permitiu observar uma grande similaridade na morfologia da interface adesiva entre os dois adesivos. Conclusões: Ambos os sistemas adesivos apresentaram um comportamento similar na adesão à dentina às 24 h. | por |
| dc.description.abstract | Objectives: To evaluate in vitro the dentin bond strength by microtensile testing of a low-cost self-etch adhesive system (OliEtch Bond, Olident, Podleze, Poland), in comparison with an already established universal adhesive system. Materials and methods: Twenty human molars extracted within the last six months, after cleaning and disinfection, were sectioned to expose dentin, followed by smear-layer simulation. The teeth were randomly assigned to two experimental groups (n= 10) according to the adhesive system used: control group SBU (Scotchbond™ Universal Plus – 3M ESPE) and experimental group OEB (OliEtch Bond – Olident), both applied according to the manufacturer’s instructions. Composite resin was then placed in 2 mm increments up to a total height of 6 mm, each increment light-cured according to the manufacturer’s instructions. The teeth were stored in artificial saliva at 37 °C for 24 h and subsequently sectioned to obtain sticks of 1 ± 0.4 mm². These were subjected to microtensile bond strength testing in a universal testing machine (1 kN; 0.5 mm/min). The mean value per tooth was considered as the experimental unit. Data were analyzed with SPSS using descriptive and inferential statistics with Student’s t-test (α = 0.05). Failure modes were classified as adhesive, cohesive, or mixed by microscopic analysis, and the adhesive interface was examined under a scanning electron microscope. Results: No statistically significant differences in dentin microtensile bond strength were observed between the two universal adhesives (t-test; p > 0.05). Adhesive failure was the most prevalent in both groups, and microscopy revealed a high similarity in the morphology of the adhesive interface between the two adhesives. Conclusions: Both adhesive systems showed similar bonding performance to dentin at 24 h. | eng |
| dc.identifier.tid | 204050987 | |
| dc.identifier.uri | http://hdl.handle.net/10400.26/59953 | |
| dc.language.iso | por | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Adesão | |
| dc.subject | Adesivos universais | |
| dc.subject | Dentina | |
| dc.subject | Microtração | |
| dc.title | Resistência adesiva à dentina por microtração de um sistema adesivo self-etch de baixo custo | por |
| dc.type | master thesis | |
| dspace.entity.type | Publication | |
| thesis.degree.name | Mestrado Integrado em Medicina Dentária |
