Repository logo
 
Publication

Fiabilidade teste-reteste, erro padrão de medida e diferença mínima detetável da plataforma BITalino R-IoT na avaliação das amplitudes de movimento ativas da coluna cervical em indivíduos assintomáticos

dc.contributor.advisorFernandes, Rita
dc.contributor.authorTrindade, Raquel
dc.date.accessioned2020-01-13T11:39:42Z
dc.date.available2020-01-13T11:39:42Z
dc.date.issued2019-12
dc.description.abstractIntrodução: A avaliação das amplitudes de movimento (ADM) da cervical é uma prática adotada pelos fisioterapeutas em utentes com dor cervical para determinar limitações no movimento, identificar a ADM em que o utente reporta os sintomas, auxiliar na tomada de decisão e diagnóstico, monitorizar e fornecer feedback acerca da efetividade das intervenções. Têm vindo a ser desenvolvidos instrumentos capazes de avaliar as diferentes variáveis cinemáticas. Apesar disso, é necessário o desenvolvimento de instrumentos que apresentem boas propriedades psicométricas, baixos-custos, com diversos sensores e de fácil utilização na resposta às necessidades identificadas na prática clínica. Foi então criada a plataforma BITalino R-IoT, que é constituída por um equipamento portátil e de fácil utilização. Objetivo: Avaliar a Fiabilidade teste-reteste, erro padrão de medida (EPM) e diferença mínima detetável (DMD) da plataforma BITalino R-IoT na avaliação das ADM ativas da coluna cervical em indivíduos assintomáticos. Metodologia: Foi utilizada uma amostra de 17 sujeitos, que participaram em dois momentos de avaliação separados por 4.3±1.3 dias. Esta avaliação consistiu na recolha e análise dos ângulos absolutos e ADM para os movimentos da cervical. Para aferir acerca da fiabilidade e a concordância, foram calculados os coeficientes de correlação intraclasse (CCI), e respetivos 95% IC, assim como os valores de EPM, respetivos 95% dos limites de concordância (LDC), a %EPM e os valores absolutos e de percentagem da DMD. Resultados: Foram obtidos moderados a excelentes valores de fiabilidade teste-reteste (>0.67), exceto no plano frontal que em alguns movimentos apresenta valores inferiores. Os valores de EPM foram inferiores a 5° em todos os planos, enquanto a DMD varia entre 5,34 e 14,46º. No que toca à %EPM e %DMD foi encontrada uma grande variação de valores (entre 2.26% e 384.70% e 5.67% e 1066.32%, respetivamente). Discussão e conclusão: Este estudo demonstrou moderada a excelente fiabilidade para a medição dos ângulos absolutos e ADM principalmente no plano sagital e transversal, e valores de EPM e DMD clinicamente aceitáveis. Foram também encontrados valores de EPM% e DMD% elevados principalmente em movimentos de menor amplitude. Os resultados obtidos suportam a utilização desta medida para a medição dos movimentos da cervical em pelo menos contextos de investigação.pt_PT
dc.description.abstractIntroduction: The assessment of cervical range of motion (ROM) is a practice adopted by physiotherapists in patients with cervical pain to assess movement limitations, identify the ROM in which patient report symptoms, assist in decision making and diagnosis, and measure the effectiveness of treatment. Instruments to evaluate different kinematic variables have been developed. Nevertheless, it’s still necessary to develop instruments with good psychometric properties, low costs, multiple sensors and easy to report to clinical practice. Therefore, the BITalino R-IoT platform was created, being a portable and easy to use equipment. Aim: Assess BITalino R-IoT platform test-retest reliability, standard error measurement (SEM) and minimal detectable change (MDC) in cervical active ROM of asymptomatic individuals. Methods: A sample of 17 subjects was evaluated in two moments separated by 4.3 ± 1.3 days. This evaluation consisted in the collection and analysis of absolute angles and ROM for cervical movements. To assess reliability and agreement, the intraclass correlation coefficients (ICC) and respective 95% CI were calculated, as well as the SEM values with 95% limits of agreement (LoA), the %SEM, the absolute value of DMD and %DMD. Results: Moderate to excellent test-retest reliability was found (> 0.67), except for the frontal plane which has lower values for some movements. The SEM were below 5° in all planes, while the DMD was between 5.34° and 14.46°. For %EPM and %DMD, a wide range of values was found (between 2.26% - 384.70% and 5.67% - 1066.32%, respectively). Discussion and Conclusion: Was demonstrated moderate to excellent reliability for measuring absolute angles and ROM, mainly in the sagittal and transverse plane, and clinically acceptable values of EPM and DMD. High %EPM and %DMD values were also found, especially in movements with smaller ROM. The obtained results support the use of this measurement for measure cervical movements in research context.pt_PT
dc.identifier.tid202372375
dc.identifier.urihttp://hdl.handle.net/10400.26/30864
dc.language.isoporpt_PT
dc.subjectCervicalpt_PT
dc.subjectFiabilidadept_PT
dc.subjectErro padrão de medidapt_PT
dc.subjectDiferença mínima detetávelpt_PT
dc.subjectAmplitude de movimentopt_PT
dc.subjectBITalino R-IoTpt_PT
dc.subjectReliabilitypt_PT
dc.subjectStandard error of measurementpt_PT
dc.subjectMinimal detectable changept_PT
dc.subjectRange of motionpt_PT
dc.titleFiabilidade teste-reteste, erro padrão de medida e diferença mínima detetável da plataforma BITalino R-IoT na avaliação das amplitudes de movimento ativas da coluna cervical em indivíduos assintomáticospt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.grantorInstituto Politécnico de Setúbal
thesis.degree.nameMestrado em Fisioterapia, área de especialização em Fisioterapia em Condições Músculo-esqueléticaspt_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
tese_raqueltrindade.pdf
Size:
2.28 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: