Percorrer por autor "Rama, Luis"
A mostrar 1 - 2 de 2
Resultados por página
Opções de ordenação
- Spatiotemporal variables comparison between drop jump and horizontal drop jump in elite jumpers and sprintersPublication . Montoro-Bombú, Raynier; Miranda-Oliveira, Paulo; Valamatos, Maria João; João, Filipa; Buurke, Tom J. W.; Santos, Amândio Cupido; Rama, LuisBackground: General expectations speculated that there are differences between drop jump (DJ) and horizontal drop jump (HDJ) exercises. While these criteria may be valid, we have yet to find a report that explores these differences in competitive level athletes. Objective: The study aimed to compare spatiotemporal variables in the drop jump (DJ) vs. the horizontal drop jump (HDJ) in elite jumpers and sprinters. Methods: Sixteen international-level male athletes performed two DJ attempts at different fall heights 0.3, 0.4, and 0.5 m (DJ30, DJ40, and DJ50), and after 2 h, they performed two HDJ attempts (HDJ30, HDJ40, HDJ50). All jumps were performed on a Kistler force plate. The variables analyzed were ground contact time (GCT), flight time (FT), eccentric phase time, concentric phase time, and time to peak concentric force. Results: The GCT was found to be significantly shorter in DJ vs. HDJ (Z = 4.980; p = 0.0001; ES = 3.11). FT was significantly lower in DJ30 versus HDJ30 (Z = 4.845; p = 0.0001, d = 3.79), but significantly higher in DJ40 vs. HDJ40 (Z = 4.437; p ≤ 0.0001, d = 3.70) and in DJ50 vs. HDJ50 (Z = 4.549; p ≤ 0.0001, d = 4.72). Conclusions: It is concluded that the HDJ requires more time for force production, that the eccentric component requires more time than the concentric and that it is not recommended to use the HDJ over the DJ for reactive purposes. This is the first study that comprehensively compare the differences between DJ and HDJ, which will assist coaches and researchers in the design of future training strategies.
- The validity of the push band 2.0 on the reactive strength index assessment in drop jumpPublication . Montoro-Bombú, Raynier; Arencibia, Lázaro de la Paz; Buzzichelli, Carlo; Miranda-Oliveira, Paulo; Fernandes, Orlando; Santos, Amândio; Rama, LuisThis study aims to verify the validity of the Push Band 2.0 (PB2.0) device on the reactive strength index (RSI) measurement, using a force plate (FP) and an optical sensor device, OptoJump (OPT), as a reference. Twenty trained athletes performed 60 drop jump trials with a height box of 30 cm. A randomized repeated measures study was conducted during a single session using the PB2.0, the OPT, and the plate force manually synchronized to obtain RSI data for each jump. Validity was analyzed by contrasting three measures: the intra-class correlation coefficient (ICC), the Bland–Altman test, and R2 coefficient of determination. Bland–Altman analysis showed that RSI and FP for PB2.0 (media = −0.047; IC 93.34%) of all data were within the confidence interval, indicating a statistically reliable result. The RSI measured by the OPT and PB2.0 also provided similar values (media = −0.047). These data are identical to other validity measures (ICC and linear correlation) but differ in the R2 values. The explained variation of PB2.0 measures attained only 29.3% of the FP (R2 = 0.293) and 29.5% (R2 = 0.295) of the OPT assessment, showing a very low determination coefficient. The results of this study point to caution in the use of PB2.0 when measuring RSI in scientific research.
