Percorrer por autor "Borga, Joana"
A mostrar 1 - 2 de 2
Resultados por página
Opções de ordenação
- 3D assessment of mandibular buccal shelf geometry for optimal micro-implant placement site in Portuguese individuals : a retrospective cone-beam computed tomography studyPublication . Borga, Joana; Bugaighis, Iman; Proença, Luís; Pereira, François Durand; Costa, Helder Nunes; Pereira, Pedro MarianoObjectives: To determine the most favourable Micro-Implant (MI) insertion site along the mandibular buccal shelf (MBS), using Cone Beam Computed Tomography (CBCT). Methods: This retrospective study assessed CBCT scans from 90 Portuguese patients (32 males and 58 females, aged 14 to 40 years). Paired MBS sites were determined. Comparative and correlation analyses were performed at p < 0.05. Results: A significant increase in MBS width was observed from the mesial to the distal direction (p < 0.001). Conversely, both the MBS steepness and cortical bone thickness significantly decreased from mesial to distal (p < 0.001). Significant negative correlation was also found between age and cortical bone thickness adjacent to the distobuccal cusp and distal tangent of both mandibular second molars (r ≤ −0.373, p ≤ 0.007). Furthermore, significant asymmetric differences were identified between the right and left MBS steepness as well as in the paired cortical bone thickness at the mesiobuccal cusp, buccal groove, and distobuccal cusp of the mandibular second molar (p ≤ 0.016). Conclusions: The results indicate that although there are sufficient MBS width and cortical bone thickness, vestibular to the mandibular second molar for MI insertion, the sites towards the distal root of the mandibular second molar are more favourable when considering MBS steepness. These findings are consistent for both sexes and apply to young and old individuals.
- 3D assessment of the relationship of the mandibular buccal shelf with the mandibular canal : a CBCT retrospective studyPublication . Feliciano, Jéssica; Pereira, Pedro Mariano; Proença, Luís; Borga, Joana; Bugaighis, ImanObjective: This study aimed to evaluate the micro-implant safest insertion site on the mandibular buccal shelf (MBS) without compromising the integrity of the mandibular canal (MC). Methods: This retrospective investigation included cone-beam computed tomography (CBCT) of 96 Portuguese patients (58 females and 38 males, average age of 25.5±10.2 years). Measurements were taken in four bilateral MBS sites buccal to the mandibular second molar; tangent to the distal surface (7D), distobuccal cusp tip (7CD), buccal groove (7S) and mesiobuccal cusp tip (7CM). The transversal MBS midpoint was also determined, and the maximum angulation from the transversal MBS midpoint was extracted relative to the true vertical plane. Subsequently, the distance from the MBS midpoint to the MC was calculated at this angulation. Descriptive and inferential statistical analyses were performed at p<0.05 Results: Significant correlations were observed among several variables and age, sex and bilateral asymmetry (p<0.05). The MBS transversal width and the distance from the MBS midpoint to the MC progressively increased in the posterior direction while the angulation decreased. Conclusion: The most appropriate micro-implant insertion location compared to the other MBS investigated sites, in the absence of impacted third molars, is adjacent to the distal surface of the second molar. This finding is consistent across all age groups, sexes, and insertion sides. However, due to the demonstrated variability, taking a CBCT scan prior to mini-implant insertion might be considered to minimize the risk of injury to the inferior alveolar nerve.
