Improvement of the energy resolution via an optimized digital signal processing in GERDA Phase I

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
1.pdf838.59 KBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

An optimized digital shaping filter has been developed for the Gerda experiment which searches for neutrinoless double beta decay in$^{76}$ Ge. The Gerda Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) corresponding to 10 % at the $Q$ value for $0\nu \beta \beta $ decay in$^{76}$ Ge is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero Area Cusp (ZAC) signal shaping filter.