Logo do repositório
 
Publicação

Point-of-care testing of nitrite in oral medicine : application and validation of an enzymatic biosensor in human saliva

datacite.subject.fosCiências Médicas::Biotecnologia Médica
datacite.subject.sdg03:Saúde de Qualidade
dc.contributor.authorGaspar, Sara Rodrigues
dc.contributor.authorProença, Luís
dc.contributor.authorAlves, Ricardo
dc.contributor.authorAlmeida, Maria Gabriela
dc.date.accessioned2026-05-19T15:25:20Z
dc.date.available2026-05-19T15:25:20Z
dc.date.issued2025-08
dc.description.abstractPeriodontal disease (PD) is a chronic inflammatory condition triggered by bacterial biofilms and progresses through two main stages: gingivitis and periodontitis. The existing diagnostic methods remain time-consuming and require clinical expertise. Salivary nitrite, a stable end-product of nitric oxide produced during inflammation, has emerged as a promising biomarker for PD. However, its reliable quantification in saliva typically relies on laboratory-based assays that are unsuited to clinical workflows. This study aimed to test and validate a new nitrite point-of-care test (POCT) for oral medicine. Building on previous research, we developed a biosensing platform based on screen-printed carbon electrodes modified with a selective enzyme, the cytochrome c nitrite reductase. To adapt bioelectrodes for salivary analysis, they were further modified with a poly(vinyl) alcohol coating and a biochemical oxygen scavenger system (ascorbate oxidase and ascorbate). The nitrite biosensor achieved a suitable linear range of 5–300 μM, with a sensitivity of 0.015 μM−1, validated against the gold-standard Griess method. Unlike the Griess reaction, the biosensor was unaffected by sample turbidity, rendering centrifugation unnecessary. Additionally, we observed that sample freezing altered nitrite concentrations, increasing levels in non-centrifuged samples, while decreasing them in previously clarified samples. These findings highlight the need for real-time analysis and call into question the reliability of previously published data that overlooked these variables. Therefore, our results demonstrate the potential of the nitrite biosensor as a novel salivary POCT and emphasize the critical need for standardized sample-handling protocols.eng
dc.identifier.citationGaspar, S. R., Proença, L., Alves, R., & Almeida, M. G. (2025). Point-of-care testing of nitrite in oral medicine - Application and validation of an enzymatic biosensor in human saliva. Sensing and Bio-Sensing Research, 49, Artigo 100860. https://doi.org/10.1016/j.sbsr.2025.100860
dc.identifier.doi10.1016/j.sbsr.2025.100860
dc.identifier.issn2214-1804
dc.identifier.urihttp://hdl.handle.net/10400.26/63200
dc.language.isoeng
dc.peerreviewedyes
dc.publisherElsevier
dc.relation.hasversionhttps://doi.org/10.1016/j.sbsr.2025.100860
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectperiodontal disease
dc.subjectsaliva
dc.subjectnitrite
dc.subjectbiosensors
dc.subjectpoint-of-care test
dc.titlePoint-of-care testing of nitrite in oral medicine : application and validation of an enzymatic biosensor in human salivaeng
dc.typecontribution to journal
dspace.entity.typePublication
oaire.citation.startPage100860
oaire.citation.titleSensing and Bio-Sensing Research
oaire.citation.volume49
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
Artigo_GabrielaAlmeida_2025_03.pdf
Tamanho:
4.67 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.85 KB
Formato:
Item-specific license agreed upon to submission
Descrição: