Name: | Description: | Size: | Format: | |
---|---|---|---|---|
10.33 MB | Adobe PDF |
Advisor(s)
Abstract(s)
Leucite and zirconia are commonly used in the production of prosthetic dental materials. Leucite presents
attractive optical properties but low toughness and wear resistance, which limits its use. Zirconia has much
higher toughness, but due to aesthetic reasons and ageing issues, needs to be glass veneered. Chipping of such
veneer is usually responsible for the abnormal wear induced on the antagonist teeth. Leucite reinforced with 25%
of nano-zirconia is a promising alternative to overcome these issues, allowing the production of dental resto-
rations without veneer. This study aims to investigate if leucite-zirconia composites have suitable optical, me-
chanical and tribological properties to be used in dental restoration. Samples with different compositions of
leucite and/or nano-zirconia were produced by unidirectional compression and characterized concerning den-
sity, surface morphology, roughness, hardness, toughness, and translucency. Wear tests were performed in a
chewing simulator using human cusps as counterbodies. Tests were also performed in glazed zirconia for com-
parison. 25% ZrO2 leads to the lowest wear of the tribological pair among the studied systems, except 100%
ZrO2. This can be attributed to the toughening effect of zirconia and reduced size of third body particles.
Abrasion was the main wear mechanism observed in this pair. In addition, this was the composite that presented
the highest translucency.
Description
Keywords
Citation
Branco, A. C., Santos, T., Polido, M., Colaço, R., Serro, A. P., & Figueiredo-Pina, C. (2022). Wear of zirconia/leucite glass-ceramics composites: A chewing simulator study. Ceramics International, 48 (4), 4604-4613