Repository logo
 
Publication

Análise de eficiência de coagulantes em estação de tratamento de água

dc.contributor.advisorFigueiredo, Catarina Isabel Cerdeira de
dc.contributor.authorCouceiro, Sónia Filipa Lindo Duarte
dc.date.accessioned2018-09-19T14:51:25Z
dc.date.available2018-09-19T14:51:25Z
dc.date.issued2018-07-25
dc.description.abstractRESUMO O estágio foi realizado no âmbito da unidade curricular “Estágio Profissionalizante” pertencente ao Mestrado em Gestão Ambiental da Escola Superior Agrária de Coimbra, e decorreu na empresa Águas do Centro Litoral, SA, na Direção de Operação de Abastecimento de Água, entre Fevereiro e Julho de 2018. O objetivo deste trabalho era determinar a taxa de tratamento ótima na remoção da turvação, com o mínimo de quantidade de alumínio na água tratada considerando o o pH, uma vez que este parâmetro tem influência no processo de coagulação e floculação. Para o desenvolvimento deste trabalho, utilizou-se o jar test. Os coagulantes estudados foram o Sulfato de Alumínio líquido (nome comercial: KEMIRA ALS-LC), o Polihidroxiclorosulfato de alumínio (nome comercial: WAC AB) e a Solução Aquosa de Sulfato Hidróxido Cloreto de Alumínio (nome comercial: WAC). O primeiro coagulante testado foi o Sulfato de Alumínio. Nos ensaios efetuados, diluído 50 vezes, variou-se o pH e a taxa de tratamento. Na análise dos resultados, e de acordo com a água no momento dos ensaios, concluiu-se que o pH ótimo foi de 7,5 com uma taxa de tratamento de 2,4 ml de coagulante por cada litro de amostra de água clorada. O segundo coagulante testado foi o WAC AB. Variando o pH e a taxa de tratamento para uma diluição de 50 vezes, concluiu-se que o pH para obtenção de melhores resultados foi de 8,0, com uma taxa de tratamento de 4,3 ml de coagulante por cada litro de amostra de água clorada. O último coagulante analisado, o WAC, também se variou o pH e a taxa de tratamento, diluído 50 vezes, chegando aos melhores resultados de turvação e alumínio com um pH de 7,5 e com uma taxa de tratamento de 4,2 ml de coagulante por cada litro de amostra de água clorada. Assim, o coagulante selecionado para o processo em estudo foi o reagente WAC, tanto a nível de resultados como de preço. Palavras-chave: Coagulação-Floculação, jar test, Coagulante, Taxa de Tratamento, pH, Alumínio ABSTRACT The internship has been prepared under the discipline "Professional Internship" for the completion of the Master in Environmental Management at Escola Superior Agrária de Coimbra. The internship took place at Águas do Centro Litoral, SA – Direção de Operação de Abastecimento de Água from the period of February to July, 2018. The goal of this work was to determinate the optimal treatment rate in the turbidity removal, with the minimum amount of aluminum in the treated water considering the pH, since this parameter has influence on the coagulation and flocculation process. The jar test was used as the development of this work . The coagulants studied were Liquid Aluminum Sulphate (trade name: KEMIRA ALS-LC), Aluminum Polyhydroxychlorosulfate (trade name: WAC AB) and Aqueous Sulphate Hydroxide Aluminum Chloride Solution (trade name: WAC). The first coagulant tested was Aluminum Sulphate. In the assays performed, diluted 50-fold, the pH and treatment rate were varied. In the analysis of the results, and according to the water at the time of the tests, it was concluded that the optimum pH was 7,5 with a treatment rate of 2,4 ml of coagulant per liter of chlorinated water sample. The second coagulant tested was WAC AB. By varying the pH and treatment rate for a 50-fold dilution, it was concluded that the pH for best results was 8,0, with a treatment rate of 4,3 ml of coagulant per liter of chlorinated water sample. The last coagulant analyzed, WAC, also varied the pH and treatment rate, diluted 50-fold, reaching the best turbidity and aluminum results with a pH of 7,5 and a treatment rate of 4,2 ml of coagulant per liter of chlorinated water sample. So, the coagulant selected for the process under study was the WAC reagent, both in terms of results and price. Key-Words: Coagulation-Flocculation, jar test, Coagulant, Treatment Rate, pH, Aluminumpt_PT
dc.identifier.tid201975556
dc.identifier.urihttp://hdl.handle.net/10400.26/24147
dc.language.isoporpt_PT
dc.subjectCoagulação-Floculaçãopt_PT
dc.subjectjar testpt_PT
dc.subjectCoagulantept_PT
dc.subjectTaxa de tratamentopt_PT
dc.subjectPHpt_PT
dc.subjectAlumíniopt_PT
dc.titleAnálise de eficiência de coagulantes em estação de tratamento de águapt_PT
dc.title.alternativecaso de estudo da Estação de Cancelas Águas do Centro Litoral (AdCL)pt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.grantorInstituto Politécnico de Coimbra

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Relatorio_Mestrado_GA_Sónia Filipa Lindo Duarte Couceiro_21627002.pdf
Size:
5.95 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: