Repository logo
 
Publication

Antidepressants detection and quantification in whole blood samples by GC–MS/MS, for forensic purposes

dc.contributor.authorTruta, Liliana
dc.contributor.authorCastro, André Lobo
dc.contributor.authorTarelho, Sónia
dc.contributor.authorCosta, Pedro
dc.contributor.authorSales, M. Goreti F.
dc.contributor.authorTeixeira, Helena M.
dc.date.accessioned2023-05-30T15:38:22Z
dc.date.available2023-05-30T15:38:22Z
dc.date.issued2016-06-23
dc.description.abstractDepression is among the most prevalent psychiatric disorders of our society, leading to an increase in antidepressant drug consumption that needs to be accurately determined in whole blood samples in Forensic Toxicology Laboratories. For this purpose, this work presents a new gas chromatography tandem mass spectrometry (GC–MS/MS) method targeting the simultaneous and rapid determination of 14 common Antidepressants in whole blood: 13 Antidepressants (amitriptyline, citalopram, clomipramine, dothiepin, fluoxetine, imipramine, mianserin, mirtazapine, nortryptiline, paroxetine, sertraline, trimipramine and venlafaxine) and 1 Metabolite (N-desmethylclomipramine). Solid-phase extraction was used prior to chromatographic separation. Chromatographic and MS/MS parameters were selected to improve sensitivity, peak resolution and unequivocal identification of the eluted analyte. The detection was performed on a triple quadrupole tandem MS in selected ion monitoring (SIM) mode in tandem, using electronic impact ionization. Clomipramine-D3 and trimipramine-D3 were used as deutered internal standards. The validation parameters included linearity, limits of detection, lower limit of quantification, selectivity/ specificity, extraction efficiency, carry-over, precision and robustness, and followed internationally accepted guidelines. Limits of quantification and detection were lower than therapeutic and subtherapeutic concentration ranges. Overall, the method offered good selectivity, robustness and quick response (<16 min) for typical concentration ranges, both for therapeutic and lethal levels.pt_PT
dc.description.versioninfo:eu-repo/semantics/acceptedVersionpt_PT
dc.identifier.citationLiliana Truta, André L. Castro, Sónia Tarelho, Pedro Costa, M. Goreti F. Sales, Helena M. Teixeira, Antidepressants detection and quantification in whole blood samples by GC–MS/MS, for forensic purposes, Journal of Pharmaceutical and Biomedical Analysis, Volume 128, 2016, Pages 496-503, https://doi.org/10.1016/j.jpba.2016.06.027.pt_PT
dc.identifier.doi10.1016/j.jpba.2016.06.027pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.26/44975
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectAntidepressantspt_PT
dc.subjectGC–MS/MSpt_PT
dc.subjectWhole bloodpt_PT
dc.subjectSolid-phase extractionpt_PT
dc.subjectForensic toxicologypt_PT
dc.titleAntidepressants detection and quantification in whole blood samples by GC–MS/MS, for forensic purposespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage503pt_PT
oaire.citation.startPage496pt_PT
oaire.citation.titleJournal of Pharmaceutical and Biomedical Analysispt_PT
oaire.citation.volume128pt_PT
person.familyNameTruta
person.familyNameLobo Castro
person.familyNameTarelho
person.familyNameTeixeira
person.givenNameLiliana
person.givenNameAndré
person.givenNameSónia
person.givenNameHelena M.
person.identifier.ciencia-idD01D-78C8-7D8B
person.identifier.ciencia-id4214-85EB-E58C
person.identifier.orcid0000-0001-8392-8776
person.identifier.orcid0000-0002-7258-8523
person.identifier.orcid0000-0001-8366-6702
person.identifier.orcid0000-0001-7570-5521
person.identifier.scopus-author-id55144024800
person.identifier.scopus-author-id7003981256
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication5ce50c4c-345f-483d-b129-d783a206d037
relation.isAuthorOfPublicationfedcfeb0-e610-4375-aa1e-5ac1fa74cd28
relation.isAuthorOfPublication631cbcb7-4c75-4fc1-b4cf-8445d428f1de
relation.isAuthorOfPublication04b8f471-69fa-4cc1-942a-7bc7e690a0d4
relation.isAuthorOfPublication.latestForDiscovery631cbcb7-4c75-4fc1-b4cf-8445d428f1de

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Manuscript.pdf
Size:
931.9 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: