Publication
Radio‐cephalic fistula recovered with drainage to median basilic vein by straightening of the forearm cephalic vein: A case report
dc.contributor.author | Costa, Luísa Lemos | |
dc.contributor.author | Matos, António Norton | |
dc.contributor.author | Almeida, Paulo | |
dc.contributor.author | Teles, Paulo | |
dc.contributor.author | Loureiro, Luís | |
dc.contributor.author | Campos, Luís | |
dc.contributor.author | Delgado, Elisabete | |
dc.contributor.author | Oliveira, Debora | |
dc.contributor.author | Campos, Tiago | |
dc.contributor.author | Inácio, Marta | |
dc.contributor.author | Fernandes, Filipa | |
dc.contributor.author | Coutinho, Sara | |
dc.contributor.author | Ventura, Ana | |
dc.contributor.author | Pereira, Susana | |
dc.contributor.author | Castro, Ana | |
dc.contributor.author | Xavier, Eva | |
dc.contributor.author | Sousa, Clemente Neves | |
dc.date.accessioned | 2022-10-21T14:45:15Z | |
dc.date.available | 2022-10-21T14:45:15Z | |
dc.date.issued | 2022 | |
dc.description.abstract | The distal arteriovenous fistula (AVF) has less complications and better patency than the proximal fistula, when it works properly. The complications of outflow of the fistula are complex, and it is necessary to analyze all solutions to solve the problem. We introduce a novel approach to solve outflow problems of a radio-cephalic AVF by straightening of the forearm cephalic vein with drainage into the median basilic vein. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Costa, L. L., de Matos, A. N., Almeida, P., Teles, P., Loureiro, L., Campos, L., Delgado, E., Oliveira, D., Campos, T., Inácio, M., Xavier, E., & Sousa, C. N. (2022). Radio-cephalic fistula recovered with drainage to median basilic vein by straightening of the forearm cephalic vein: A case report. Seminars in Dialysis. | pt_PT |
dc.identifier.doi | 10.1111/sdi.13096 | pt_PT |
dc.identifier.eissn | 1525-139X | |
dc.identifier.uri | http://hdl.handle.net/10400.26/42012 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Wiley | pt_PT |
dc.relation.publisherversion | https://doi.org/10.1111/sdi.13096 | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | pt_PT |
dc.subject | Radio-cephalic fistula | pt_PT |
dc.subject | Arteriovenous fistula | pt_PT |
dc.subject | Hemodialysis | pt_PT |
dc.title | Radio‐cephalic fistula recovered with drainage to median basilic vein by straightening of the forearm cephalic vein: A case report | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.title | Seminars in Dialysis | pt_PT |
person.identifier.ciencia-id | E215-041D-F66F | |
person.identifier.orcid | 0000-0003-2654-0497 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | f794ca21-68d8-4e4e-b8dc-4d10ef6f3f2f | |
relation.isAuthorOfPublication.latestForDiscovery | f794ca21-68d8-4e4e-b8dc-4d10ef6f3f2f |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Radio‐cephalic fistula recovered with drainage to median basilic vein by.pdf
- Size:
- 4.72 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.85 KB
- Format:
- Item-specific license agreed upon to submission
- Description: