The establishment of computed tomography diagnostic reference levels in Portugal

dc.contributor.authorSantos, Joana
dc.contributor.authorFoley, Shane
dc.contributor.authorPaulo, Graciano
dc.contributor.authorMcEntee, Mark
dc.contributor.authorRainford, Louise
dc.date.accessioned2017-04-13T10:17:20Z
dc.date.available2017-04-13T10:17:20Z
dc.date.issued2014
dc.description.abstractThe aims of this study were to investigate the frequency of Portuguese computed tomography (CT) examinations, identify protocol application and establish diagnostic reference levels (DRLs). CT departments (n=5211) were surveyed nationally (June 2011-January 2012) and CT protocol information and dose data were collected, as were retrospective age-categorised paediatric CT data from three national paediatric centres. The proposed national CT DRLs (CTDIvol) for adults were 75, 18, 14, 18, 17, 36, 22, 27 and 16 mGy for head, neck, chest, abdomen, pelvis, cervical, dorsal, lumbar and joints, respectively. The levels for paediatric head and chest examinations were as follows: 48 and 2 mGy (newborns), 50 and 6 mGy (5 y olds), 70 and 6 mGy (10 y olds) and 72 and 7 mGy (15 y olds). A limited number of current paediatric protocols aligned to recommended international age categorisations. Portuguese DRLs were generally higher than European recommendations, suggesting potential for optimisation. The need for greater standardisation of age-categorised paediatric protocols was identified.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1093/rpd/nct226pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.26/18186
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherOxford University Presspt_PT
dc.subjectAdolescentpt_PT
dc.subjectAdultpt_PT
dc.subjectChildpt_PT
dc.subjectPreschool Childpt_PT
dc.subjectFemalept_PT
dc.subjectHumanspt_PT
dc.subjectInfantpt_PT
dc.subjectNewborn Infantpt_PT
dc.subjectMalept_PT
dc.subjectPortugalpt_PT
dc.subjectRadiation Dosagept_PT
dc.subjectRadiometrypt_PT
dc.subjectReference Standardspt_PT
dc.subjectRiskpt_PT
dc.subjectX-Ray Computed Tomographypt_PT
dc.titleThe establishment of computed tomography diagnostic reference levels in Portugalpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage317pt_PT
oaire.citation.issue3pt_PT
oaire.citation.startPage307pt_PT
oaire.citation.titleRadiation Protection Dosimetrypt_PT
oaire.citation.volume158pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The establishment of computed tomography diagnostic reference levels in Portugal.pdf
Size:
192 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: