Publication
LUX Cryogenics and Circulation
| dc.contributor.author | Bradley, A.W. et al. (67 authors) | |
| dc.contributor.author | de Viveiros, L. | |
| dc.contributor.author | Lindote, A. | |
| dc.contributor.author | Lopes, M.I. | |
| dc.contributor.author | Neves, F. | |
| dc.contributor.author | Da Cunha, J. Pinto | |
| dc.contributor.author | Silva, C. | |
| dc.contributor.author | Solovov, V.N. | |
| dc.date.accessioned | 2019-02-04T04:47:01Z | |
| dc.date.available | 2019-02-04T04:47:01Z | |
| dc.date.issued | 2012-03-14 | |
| dc.date.updated | 2019-02-04T04:47:01Z | |
| dc.description.abstract | We report the effciency of a thermosyphon-based cooling system for a liquid xenon (LXe) time projection chamber (TPC), as well as the effciency of a unique internal heat exchanger with standard gas phase purification using a heated getter, which allows for very high flow purification without requiring large cooling power. | |
| dc.description.version | Peer Reviewed | |
| dc.identifier | Phys.Procedia 37 (2012) 1122-1130; DOI 10.1016/j.phpro.2012.03.734 | |
| dc.identifier.uri | http://dx.doi.org/10.1016/j.phpro.2012.03.734 | |
| dc.identifier.uri | http://hdl.handle.net/10400.26/26676 | |
| dc.language.iso | eng | |
| dc.title | LUX Cryogenics and Circulation | |
| dc.type | journal article | |
| dspace.entity.type | Publication | |
| rcaap.rights | openAccess | pt |
| rcaap.type | article |