We report the effciency of a thermosyphon-based cooling system for a liquid xenon (LXe) time projection chamber (TPC), as well as the effciency of a unique internal heat exchanger with standard gas phase purification using a heated getter, which allows for very high flow purification without requiring large cooling power.