Repository logo
 
Publication

Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics

dc.contributor.authorVerbus, J.R.
dc.contributor.authorRhyne, C.A.
dc.contributor.authorMalling, D.C.
dc.contributor.authorGenecov, M.
dc.contributor.authorGhosh, S.
dc.contributor.authorMoskowitz, A.G.
dc.contributor.authorChan, S.
dc.contributor.authorChapman, J.J.
dc.contributor.authorde Viveiros, L.
dc.contributor.authorFaham, C.H.
dc.contributor.authorFiorucci, S.
dc.contributor.authorHuang, D.Q.
dc.contributor.authorPangilinan, M.
dc.contributor.authorTaylor, W.C.
dc.contributor.authorGaitskell, R.J.
dc.date.accessioned2019-02-04T11:00:19Z
dc.date.available2019-02-04T11:00:19Z
dc.date.issued2017-04-11
dc.date.updated2019-02-04T11:00:19Z
dc.description.abstractWe propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galactic halo. This technique provides an $\textit{in situ}$ measurement of the low-energy nuclear recoil response of the target media using the measured scattering angle between multiple neutron interactions within the detector volume. The low-energy reach and reduced systematics of this calibration have particular significance for the low-mass WIMP sensitivity of several leading dark matter experiments. Multiple strategies for improving this calibration technique are discussed, including the creation of a new type of quasi-monoenergetic 272 keV neutron source. We report results from a time-of-flight based measurement of the neutron energy spectrum produced by an Adelphi Technology, Inc. DD108 neutron generator, confirming its suitability for the proposed nuclear recoil calibration.
dc.description.versionPeer Reviewed
dc.identifierNucl.Instrum.Meth. A851 (2017) 68-81 Nucl. Instrum. Methods A851, 68 (2017); DOI 10.1016/j.nima.2017.01.053
dc.identifier.urihttp://dx.doi.org/10.1016/j.nima.2017.01.053
dc.identifier.urihttp://hdl.handle.net/10400.26/27165
dc.language.isoeng
dc.titleProposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics
dc.typejournal article
dspace.entity.typePublication
rcaap.rightsopenAccesspt
rcaap.typearticle

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1.pdf
Size:
8.25 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.85 KB
Format:
Item-specific license agreed upon to submission
Description: