Browsing by Author "Maneira, J."
Now showing 1 - 10 of 11
Results Per Page
Sort Options
- Calibration of the SNO+ experimentPublication . Maneira, J.; Falk, E.; Leming, E.; Peeters, S.The main goal of the SNO+ experiment is to perform a low-background and high-isotope-mass search for neutrinoless double-beta decay, employing 780 tonnes of liquid scintillator loaded with tellurium, in its initial phase at 0.5% by mass for a total mass of 1330 kg of (130)Te. The SNO+ physics program includes also measurements of geo- and reactor neutrinos, supernova and solar neutrinos. Calibrations are an essential component of the SNO+ data-taking and analysis plan. The achievement of the physics goals requires both an extensive and regular calibration. This serves several goals: the measurement of several detector parameters, the validation of the simulation model and the constraint of systematic uncertainties on the reconstruction and particle identification algorithms. SNO+ faces stringent radiopurity requirements which, in turn, largely determine the materials selection, sealing and overall design of both the sources and deployment systems. In fact, to avoid frequent access to the inner volume of the detector, several permanent optical calibration systems have been developed and installed outside that volume. At the same time, the calibration source internal deployment system was re-designed as a fully sealed system, with more stringent material selection, but following the same working principle as the system used in SNO. This poster described the overall SNO+ calibration strategy, discussed the several new and innovative sources, both optical and radioactive, and covered the developments on source deployment systems.
- Combined Analysis of all Three Phases of Solar Neutrino Data from the Sudbury Neutrino ObservatoryPublication . SNO collaboration (123 authors); Barros, N.; Maneira, J.; Prior, G.; Chauhan, D.We report results from a combined analysis of solar neutrino data from all phases of the Sudbury Neutrino Observatory. By exploiting particle identification information obtained from the proportional counters installed during the third phase, this analysis improved background rejection in that phase of the experiment. The combined analysis resulted in a total flux of active neutrino flavors from 8B decays in the Sun of (5.25 \pm 0.16(stat.)+0.11-0.13(syst.))\times10^6 cm^{-2}s^{-1}. A two-flavor neutrino oscillation analysis yielded \Deltam^2_{21} = (5.6^{+1.9}_{-1.4})\times10^{-5} eV^2 and tan^2{\theta}_{12}= 0.427^{+0.033}_{-0.029}. A three-flavor neutrino oscillation analysis combining this result with results of all other solar neutrino experiments and the KamLAND experiment yielded \Deltam^2_{21} = (7.41^{+0.21}_{-0.19})\times10^{-5} eV^2, tan^2{\theta}_{12} = 0.446^{+0.030}_{-0.029}, and sin^2{\theta}_{13} = (2.5^{+1.8}_{-1.5})\times10^{-2}. This implied an upper bound of sin^2{\theta}_{13} < 0.053 at the 95% confidence level (C.L.).
- Current Status and Future Prospects of the SNO+ ExperimentPublication . SNO+ collaboration (156 authors); Andringa, S.; Barros, N.; Carvalho, J.; Chauhan, D.; Lozza, V.; Maio, A.; Maneira, J.; Prior, G.SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m diameter acrylic vessel which will be filled with about 780 tonnes of ultra-pure liquid scintillator. Designed as a multipurpose neutrino experiment, the primary goal of SNO+ is a search for the neutrinoless double-beta decay (0$\nu\beta\beta$) of 130Te. In Phase I, the detector will be loaded with 0.3% natural tellurium, corresponding to nearly 800 kg of 130Te, with an expected effective Majorana neutrino mass sensitivity in the region of 55-133 meV, just above the inverted mass hierarchy. Recently, the possibility of deploying up to ten times more natural tellurium has been investigated, which would enable SNO+ to achieve sensitivity deep into the parameter space for the inverted neutrino mass hierarchy in the future. Additionally, SNO+ aims to measure reactor antineutrino oscillations, low-energy solar neutrinos, and geoneutrinos, to be sensitive to supernova neutrinos, and to search for exotic physics. A first phase with the detector filled with water will begin soon, with the scintillator phase expected to start after a few months of water data taking. The 0$\nu\beta\beta$ Phase I is foreseen for 2017.
- Measurement of the $\nu_e$ and Total $^{8}$B Solar Neutrino Fluxes with the Sudbury Neutrino Observatory Phase-III Data SetPublication . SNO collaboration (150 authors); Barros, N.; Chauhan, D.; Maneira, J.; Prior, G.This paper details the solar neutrino analysis of the 385.17-day phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of 3He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active 8B solar neutrino flux was largely independent of the methods employed in previous phases. The total flux of active neutrinos was measured to be 5.54−0.31+0.33(stat.)−0.34+0.36(syst.)×106 cm−2 s−1, consistent with previous measurements and standard solar models. A global analysis of solar and reactor neutrino mixing parameters yielded the best-fit values of Δm2=7.59−0.21+0.19×10−5eV2 and θ=34.4−1.2+1.3degrees.
- Neutron detection in the SNO+ water phasePublication . SNO+ collaboration (21 authors); Andringa, S.; Barão, F.; Maneira, J.SNO+ is a multipurpose neutrino experiment located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector started taking physics data in May 2017 and is currently completing its first phase, as a pure water Cherenkov detector. The low trigger threshold of the SNO+ detector allows for a substantial neutron detection efficiency, as observed with a deployed ^{241}Am^{9}Be source. Using a statistical analysis of one hour AmBe calibration data, we report a neutron capture constant of 208.2 + 2.1(stat.) us and a lower bound of the neutron detection efficiency of 46% at the center of the detector.
- Search for neutron-antineutron oscillations at the Sudbury Neutrino ObservatoryPublication . SNO collaboration (124 authors); Barros, N.; Chauhan, D.; Maneira, J.; Prior, G.Tests on B-L symmetry breaking models are important probes to search for new physics. One proposed model with Δ(B-L)=2 involves the oscillations of a neutron to an antineutron. In this paper, a new limit on this process is derived for the data acquired from all three operational phases of the Sudbury Neutrino Observatory experiment. The search concentrated on oscillations occurring within the deuteron, and 23 events were observed against a background expectation of 30.5 events. These translated to a lower limit on the nuclear lifetime of 1.48×1031 yr at 90% C.L. when no restriction was placed on the signal likelihood space (unbounded). Alternatively, a lower limit on the nuclear lifetime was found to be 1.18×1031 yr at 90% C.L. when the signal was forced into a positive likelihood space (bounded). Values for the free oscillation time derived from various models are also provided in this article. This is the first search for neutron-antineutron oscillation with the deuteron as a target.
- Tests of Lorentz invariance at the Sudbury Neutrino ObservatoryPublication . SNO collaboration (133 authors); Barros, N.; Chauhan, D.; Maneira, J.; Prior, G.Experimental tests of Lorentz symmetry in systems of all types are critical for ensuring that the basic assumptions of physics are well-founded. Data from all phases of the Sudbury Neutrino Observatory, a kiloton-scale heavy water Cherenkov detector, are analyzed for possible violations of Lorentz symmetry in the neutrino sector. Such violations would appear as one of eight possible signal types in the detector: six seasonal variations in the solar electron neutrino survival probability differing in energy and time dependence, and two shape changes to the oscillated solar neutrino energy spectrum. No evidence for such signals is observed, and limits on the size of such effects are established in the framework of the Standard Model Extension, including 40 limits on perviously unconstrained operators and improved limits on 15 additional operators. This makes limits on all minimal, Dirac-type Lorentz violating operators in the neutrino sector available for the first time.
- The calibration system for the photomultiplier array of the SNO+ experimentPublication . SNO+ collaboration (23 authors); Alves, R.; Andringa, S.; Carvalho, J.; Chauhan, D.; Gurriana, L.; Maio, A.; Maneira, J.; Seabra, L.A light injection system using LEDs and optical fibres was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. Large volume, non-segmented, low-background detectors for rare event physics, such as the multi-purpose SNO+ experiment, need a calibration system that allow an accurate and regular measurement of the performance parameters of their photomultiplier arrays, while minimising the risk of radioactivity ingress. The design implemented for SNO+ uses a set of optical fibres to inject light pulses from external LEDs into the detector. The design, fabrication and installation of this light injection system, as well as the first commissioning tests, are described in this paper. Monte Carlo simulations were compared with the commissioning test results, confirming that the system meets the performance requirements.
- The Laser calibration of the Atlas Tile Calorimeter during the LHC run 1Publication . ATLAS Tile Calorimeter system collaboration (238 authors); Santos, S.P.Amor Dos; Araque, J.P.; Castro, A.Blanco; Carvalho, J.; Castro, N.F.; De Sousa, M.J.Da Cunha Sargedas; Fiolhais, M.C.N.; Galhardo, B.; Gomes, A.; Jorge, P.M.; Martins, P.J.Magalhaes; Maio, A.; Maneira, J.; Seabra, L.F.Oleiro; Onofre, A.; Pedro, R.; Pina, J.; Santos, H.; Saraiva, J.G.; Silva, J.; Delgado, A.Tavares; Veloso, F.This article describes the Laser calibration system of the Atlas hadronic Tile Calorimeter that has been used during the run 1 of the LHC. First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Finally, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.
- The LED and fiber based calibration system for the photomultiplier array of SNO+Publication . SNO+ collaboration (22 authors); Seabra, L.; Alves, R.; Andringa, S.; Carvalho, J.; Gurriana, L.; Maio, A.; Maneira, J.A new external LED/fiber light injection calibration system was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. The goal of the calibration system is to allow an accurate and regular measurement of the photomultiplier array's performance, while minimizing the risk of radioactivity ingress. The choice in SNO+ was to use a set of optical fiber cables to convey into the detector the light pulses produced by external LEDs. The quality control was carried out using a modified test bench that was used in QC of optical fibers for TileCal/ATLAS. The optical fibers were characterized for transmission, timing and angular dispersions. This article describes the setups used for the characterization and quality control of the system based on LEDs and optical fibers and their results.