Repository logo
 
Publication

Car seat challenge test in the Neonatal Intensive Care Unit

dc.contributor.authorBrás, Ana
dc.contributor.authorPratinha, Cristina
dc.contributor.authorOliveira, Susana
dc.contributor.authorBarbieri-Figueiredo, MC
dc.contributor.authorRamos, Madalena
dc.contributor.authorGuimarães, Hercília
dc.date.accessioned2020-06-03T11:21:35Z
dc.date.available2020-06-03T11:21:35Z
dc.date.issued2019
dc.description.abstractBackground: In Portugal, there is a Guideline of the Directorate General of Health that requires that newborns with hospital discharge should be transported home in a proper and safe restraint system, aligned with AAP policy statements. In the Neonatal Intensive Care Unit (NICU) of Centro Hospitalar Universitário de S. João (Porto, Portugal), the Car Seat Challenge Test has been carried out since 2005, and there is not any study about its safety. Objective: This study aims to report the responses of preterm infants discharged home in 2015 and to develop a standardized procedure for its performance. Methods: This is a descriptive, retrospective, observational, nonexperimental study. Data was collected from the NICU nursing records with a form designed for this purpose. Study variables were: gender, gestational age, birth weight, and comorbidities. Saturation of oxygen in arterial blood (SpO2) and heart rate (HR) values were measured at rest (in the crib), in the car seat chair at time 0, 5, 15, 30, 45 and 60 minutes. Results: During the year 2015, 86 preterm infants were discharged home, and all had values of SpO2 and HR within the reference range for this age group, during the Car Seat Challenge Test. The values decrease slightly from the measurement at 15 minutes for both SpO2 and HR. Infants with and without comorbidities had similar values of SpO2 (97-99.5%) and HR (135- 155 beats per minute [bpm]), with a small decrease at 15 minutes. Infants with comorbidities did not regain saturation values after 30 minutes. Conclusion: The Car Seat Challenge Test has been performed systematically in the NICU since 2005. Data analyzed demonstrated it is safe. A standardized procedure was developed to provide harmonization of criteria.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.issn22810692
dc.identifier.urihttp://hdl.handle.net/10400.26/32474
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherHygeia Press di Corridori Marinellapt_PT
dc.relation.publisherversionwww.jpnim.compt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectInfant, prematurept_PT
dc.subjectChild restraint systemspt_PT
dc.subjectIntensive care units neonatalpt_PT
dc.titleCar seat challenge test in the Neonatal Intensive Care Unitpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceCagliari - Italypt_PT
oaire.citation.endPage9pt_PT
oaire.citation.issue2pt_PT
oaire.citation.startPage1pt_PT
oaire.citation.titleThe Journal of Pediatric and Neonatal Individualized Medicinept_PT
oaire.citation.volume8pt_PT
person.familyNameBarbieri-Figueiredo
person.givenNameMC
person.identifier.ciencia-id7212-3EC5-34CE
person.identifier.orcid0000-0003-0329-0325
person.identifier.ridF-4264-2015
person.identifier.scopus-author-id39361079000
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationce37f804-c848-4341-88c9-928ddbcab1d1
relation.isAuthorOfPublication.latestForDiscoveryce37f804-c848-4341-88c9-928ddbcab1d1

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
artigos afiliados-23.pdf
Size:
1.4 MB
Format:
Adobe Portable Document Format